LIMITED WARRANTY

TABLE OPTIONS

To the original purchaser only, Clinton Industries warrants manufactured products to be free of defects in materials, 

workmanship or design under normal use and service conditions for five years on all mechanical products, all electric 

equipment and support items, from the date of purchase. Original purchaser 

MUST REGISTER THIS WARRANTY by 

mail or online at www.clinton-ind.com/warranty registration

 within 30 days of purchase to claim  

benefits offered by this warranty. Failure to register your product with in the allotted time voids all offers and benefits 

of this warranty.

If the product and/or equipment should become defective within the first year of the warranty period, Clinton Industries will repair or 

replace it (at our discretion) free of charge, including return transportation to you provided you deliver the equipment or product prepaid 

to Clinton Industries located at 1140 Edison St, York, PA, 17403.  If replacement parts are deemed necessary  by Clinton Industries within 

(1) one year of the purchase date, all new parts and shipping will be covered by Clinton Industries. Thereafter in warranted years (2) two 

through (5) five, all shipping charges of replacement parts or replacement product (at our discretion) covered under this warranty will be the 

responsibility of the purchaser.

Please receive authorization before returning product to the factory, as Clinton Industries will not accept collect shipments.  Clinton 

Industries reserves the right to repair or replace component parts without return of the entire unit.  Service can be conducted on Clinton 

power tables by a trained, fully self-insured, professional service technician.

This warranty does not include damage resulting from accident, abuse or misuse of the product and expressly excludes normal wearing  

of parts (including but not limited to vinyl) or defect caused by transportation, accident, fire, flood, improper assembly, alteration, or  

negligence. In addition all representations and warranties made by any person or entity other than Clinton Industries main office is excluded 

from this warranty.

Implied warranties, including those of merchantability and fitness for a particular purpose, are limited to five years from purchase and all 

implied warranties are expressly excluded to the extent permitted by law and are otherwise limited to the terms of express warranties as set 

forth above.  This is the exclusive remedy, and law for consequential or incidental damages under any and all warranties is excluded to the 

extent exclusion permits liability.

This warranty does not cover or compensate for any loss of use damages that may occur as a result of failure of equipment covered under 

this warranty. 

Clinton industries reserves the right to alter or change equipment without prior notice and to repair or replace warranted equipment with 

new parts or new products.

Note: Exceeding the recommended weight capacity of any Clinton product with stationary weight or a total combined weight consisting of 

stationary weight and applied force under normal intended or unintended use voids this and all implied or stated warranties.

Limited Warranty

ON FRAME & 

ELECTRICAL

COMPONENTS

Limited

Warranty

 

080

 

082

 

083

 

084

 

087

Option: 080 Safety Straps

Length ............................................................... 92"

Width .................................................................. 2"

Intended Use:

Safety straps are intended to help to secure a normal 

patient on the table. Not intended to restrain unruly 

or mentally unstable patients. Patients should not be 

left unattended on the table.

Option: 082 Chrome Safety Rail

Length ............................................................... 24"

Height ................................................................. 8"

Intended Use:

Safety rails are intended to help prevent patients 

from inadvertently rolling off the table. Patients 

should not be left unattended on the table.

Option: 083 2-Hook IV Pole and Mounting Bracket

Height Range ......................................................... "

Also available with 4-hook top

Intended Use:

IV pole and mounting bracket are intended to  

integrate IV hook-up with the table

Option: 087 Locking Casters

Caster Diameter ................................................... 3"

Intended Use: 

Locking Casters are intended to lock the casters and 

prevent the individual wheels from turning or rolling.

Option: 084 Hand-Held Height Control

Intended Use:

Hand held table controller is intended to be an  

alternative to the foot controller.

 

Summary of Contents for 84100

Page 1: ...R I C O P E N B A S E P O W E R TA B L E S C o m b i n e L o a d a n d F o r c e C a p a c i t y 5 5 0 l b s 2 4 9 k g Model Numbers 84100 84200 84430 Limited Warranty ON FRAME ELECTRICAL COMPONENTS Limited Warranty CLI MA 005 REV A ...

Page 2: ...h a comfortable 2 padded surface covered in tough woven back vinyl upholstery The pivot points are self lubricating and the smooth vertical adjustment is powered by a dependable 120v motor Models 84200 and 84430 are equipped with a pneumatic backrest that can be accessed from either side The foot controller on all models features an up button and a down button that controls the operation of the ta...

Page 3: ...ng a problem Pay particular attention to Cautions and Warnings throughout this manual Potentially hazardous and harmful situations to users patients and property can occur if these cautions and warnings are ignored PARTS SAFETY Premium woven back upholstery Plywood Top Seamless rounded corners HEAD END Adjustable Backrest Actuator Lever 1 on each side models 80200 84430 only Top Frame Center Leg C...

Page 4: ...o 90 Operation Temperature 50º F to 100º F Humidity 30 to 75 WARNING When performing any procedure that requires use of electrical instruments or equipment the patient must be insulated fron the metal portions of the table with non conductive material Failure to do so mat result in electrical shock or injury to the patient or attendant WARNING Always use 110v 60hz alternating current Failure to us...

Page 5: ...e the upholstery during the unpacking process CAUTION Clinton Open Base Power Tables are heavy Clinton Industries recommends four reasonably strong individuals using proper lifting techniques be used to lift or move the table Not using the recommended number of movers may result in injury to the persons attempting to lift or move the equipment CAUTION Always lift the table by the metal frame If ta...

Page 6: ...e foot controller with slight even pressure and the table will slowly go down to minimum level Slight even pressure on the up button will slowly raise the table to maximum height CLEAN BEFORE USING All Models It is important to thoroughly clean tables according to facility standards before it is put into service See cleaning suggestions on page 8 of this manual ADJUSTABLE BACKREST Models 84200 844...

Page 7: ... the drop section will lock into position wherever the lifting motion is stopped NEVER LUBRICATE THE LIFT MECHANISM Drop Section in the semi raised position Drop Section in the down position OPTIONAL LOCKING CASTERS All Models Locking casters are an option on all models The locking mechanism can be engaged by using your foot to depressing the tab located at the rear of each caster This action lock...

Page 8: ...ccording to standard procedures of your particular healthcare or therapy facility Although Clinton recommends a cleaning solution it is not a guarantee that it will meet with your facility s standards or state federal and local standards for treatment and cleaning of areas and equipment that may be exposed to pathogens and infectious materials PERIODIC INSPECTION Inspect all electrical cords and c...

Page 9: ...ions and warranties made by any person or entity other than Clinton Industries main office is excluded from this warranty Implied warranties including those of merchantability and fitness for a particular purpose are limited to five years from purchase and all implied warranties are expressly excluded to the extent permitted by law and are otherwise limited to the terms of express warranties as se...

Page 10: ...en nut A and tighten nut B If headrest does not move at all loosen nut B and tighten nut A After proper function has been achieved tighten both nuts Slide Block 4 total Base and Top Frame Lubricate using Molykote G 0052Fg grease top and bottom contact points Base Top Frame End Plug Back Rest Back Rest Actuator Arm Back Rest Cylinder Foot Lift Actuator Arm Motor Center Axle Lubricate using Molykote...

Page 11: ... not covered in this guide or questions about your Clinton Power Table please call Clinton Industries at 800 441 9131 REMOVAL OF THE MOTOR FOR SERVICE The motor assembly is located at the foot end of the table on the base Next detach the motor assembly If possible raise the table to its highest position Raising the table will make it easier to remove the motor mount bolts Using help lower the tabl...

Reviews: