AIR-CONDITIONERS
COMPACT and SPLIT QUATTRO models
page 34
www.climma.it
TABLE
The connections between compressor unit and evaporator must be made by the installer. The compres-
sor unit and the evaporator are pressurized with dry air and nitrogen, NOT refrigerant.
Refrigerant grade copper pipe must be used for the connecting lines. Do NOT use standard plumbing
copper pipe.
The connections are made by flare connections (45° angle).
Insulate each pipe individually.
-Maximum distance between compressor unit and evaporator = 15 m.
-Maximum height difference between compressor unit and evaporator = 5 m.
UNITS WITH REFRIGERANT R407C
SPLIT 10 / SPLIT 12 / SPLIT 16 / SPLIT 17 SLIM / SPLIT 24 SLIM.
The connection for refrigerant pipes, must be made by a qualified engineer.
##