67
EN
5.7
Sensors
The sensors installed have the following characteristics:
– Dual sensor (thermal safety/output) NTC R25°C; 10kΩ β25°-
85°C: 3435
– domestic hot water sensor NTC R25°C; 10kΩ β25°-85°C: 3435
– External temperature sensor NTC R25°C; 10kΩ β25°-85°C:
3435
Correspondence of Temperature Detected/Resistance
Examples of reading:
TR=75°C → R=1925Ω
TR=80°C → R=1669Ω.
TR
0°C 1°C 2°C 3°C 4°C 5°C 6°C 7°C 8°C 9°C
Resistance R (Ω)
0°C 27279
17959
12090
8313
5828
4161
3021
2229
1669
1266
973
26135
17245
11634
8016
5630
4026
2928
2164
1622
1232
25044
16563
11199
7731
5440
3897
2839
2101
1577
1199
24004
15912
10781
7458
5258
3773
2753
2040
1534
1168
23014
15289
10382
7196
5082
3653
2669
1982
1491
1137
22069
14694
9999
6944
4913
3538
2589
1925
1451
1108
21168
14126
9633
6702
4751
3426
2512
1870
1411
1079
20309
13582
9281
6470
4595
3319
2437
1817
1373
1051
19489
13062
8945
6247
4444
3216
2365
1766
1336
1024
18706
12565
8622
6033
4300
3116
2296
1717
1300
998
10°C
20°C
30°C
40°C
50°C
60°C
70°C
80°C
90°C
100°C
5.8
Expansion vessel
The expansion vessel installed on the boilers has the following
characteristics:
24 OF
Description
U/M
Climit
24 OF
Total capacity
l
8,0
Prefilling pressure
kPa
100
bar
1,0
Useful capacity
l
4,0
Maximum system content (*)
l
109
24 BF
-
28 BF
-
38 BF
Description
U/M
Climit
24 BF
28 BF
38 BF
Total capacity
l
8,0
9,0
9,0
Prefilling pressure
kPa
100
100
100
bar
1,0
1,0
1,0
Useful capacity
l
4,0
5,0
5,0
Maximum system content (*)
l
109
124
124
(*) Conditions of:
Average operating temperature 70°C (with high temperature
system 80/60°C)
Start temperature at system filling 10°C.
m
CAUTION
– For systems with water content exceeding the ma-
ximum system content (as indicated in the table) an
additional expansion vessel must be prearranged.
– The difference in height between the relief valve and
the highest point of the system cannot exceed 6 me-
tres. If the difference is greater than 6 metres, incre-
ase the prefilling pressure of the expansion vessel
and the system when cold by 0.1 bar for each meter
increase.
5.9
Circulation pump
The flow-head performance curve available for the heating sy-
stem is shown in the graph below.
24 OF
RESIDUAL HEAD (mbar)
0
0
800 1000 1200 1400
1600
600
400
200
100
200
300
400
500
600
24 OF
FLOW (l/h)
Fig. 16
24 BF
-
28 BF
-
38 BF
RESIDUAL HEAD (mbar)
0
0
800 1000 1200 1400
1600
600
400
200
100
200
300
400
500
600
24 BF
28 BF
38 BF
FLOW (l/h)
Fig. 17
Summary of Contents for 24 BF
Page 10: ...10 FR ...
Page 49: ...49 FR ...
Page 58: ...58 EN ...
Page 97: ...97 EN ...
Page 98: ...98 ...
Page 99: ...99 ...
Page 100: ...Via Garbo 27 37045 Legnago Vr Tel 39 0442 631111 Fax 39 0442 631292 ...
Page 101: ...Via Garbo 27 37045 Legnago Vr Tel 39 0442 631111 Fax 39 0442 631292 ...
Page 102: ...51 ...
Page 103: ...50 ...
Page 104: ...49 ...
Page 143: ...10 ...