17
CTK 190 mobile air dehumidifier
•
The units are operated with
230V / 50Hz alternating
current
•
The electrical connection is
established using a built-in
mains cable with earthed safety
plug
•
Extensions to the connection
cable may only be carried out
by authorised electricians,
subject to the length of
the cable, connected load
of the unit and taking into
consideration how the unit is
used at its location
9. 0 Electrical wiring
NOTE
The electrical connection to the
units must be made at feed-
points with residual current
devices in accordance with
VDE 0100, Section 704.
When installing the units in
extremely damp environments
such as laundry rooms, showers
etc., the unit must secured with a
residual current device provided
by the customer in accordance
with the regulations.
CAUTION!
All cable extensions must only be
used in fully unreeled or reeled
off condition.
10.0 Electrical wiring diagram
230V~50Hz
L
N
B
R
A
U
N
B
LA
U
PE
G
R
Ü
N
/G
E
LB
BLAU
R
O
T
Kompressor
Kondensator
Kondensator
BLAU
WEISS
OLP
W
E
IS
S
B
LA
C
K
Ventilator
CN1
C
N
2
CN3
CN4
T. Sensor
Bedienplatine
F. Sensor
FUSE
P3
P4
P9
T1AL 250V
BLAU
P5
P12
P1
BLAU
ROT
B
LA
U
2-Wege
Magnet-
ventil
Mikro-
schalter
Capacitor
Capacitor
Compressor
FUSE
H. probe
Operating board
BLUE
T. probe
Microswitch
Fan
2-way
solenoid
valve
BLUE
BLUE
RED
BLUE
WHITE
WHITE
BLACK
BLUE
BLUE
BROWN
GREEN/YELLOW
OLP
RED
Fuse