11
CM2026
Home Weather Station
Programme Mode
Quick Display Mode:
While on the home screen, press the
SET
key to enter the Quick Display mode.
Pressing the
SET
key multiple times will scroll through the following values:
-
Wind speed
- Pressing the
+
key while viewing this figure will toggle between
Wind speed and Gust speed.
-
Rainfall figures
- Pressing the + key will scroll through the selectable time
periods of 1 hour, 24 hours, week, month and total. If you need to clear
your rainfall reading, use + to scroll until you are viewing the total reading,
then press and hold
SET
for two seconds to reset this value to zero.
-
Outdoor Temperature / Wind Chill / Dew Point
– Press the
+
key to scroll
between these three measurements.
Calibration Mode
To enter the Calibration Mode, press and hold the
HISTORY
key for eight seconds.
You can then press the
SET
key to scroll through each menu and press the
+
or
MIN/MAX
keys to increase or decrease the values accordingly. To exit the
Calibration mode press the
HISTORY
key at any time.
Calibration options are as follows:
-
Wind Speed Calibration (Default 1.0, adjustment range 0.75 to 1.25)
-
Rainfall Data Calibration (Default 1.0, adjustment range 0.75 to 1.25)
-
Historic Rainfall Calibration
-
Outdoor Humidity Calibration
-
Outdoor Temperature Calibration
-
Indoor Humidity Calibration
-
Indoor Temperature Calibration
Please take care when changing any data, as certain figures will affect other
measurements calculated by your console. For example, the wind chill
measurement will be worked out using a combination of the wind speed and
outdoor temperature readings. Therefore, if the outdoor temperature reading is
calibrated using this menu, please be wary that this would also change the
calculation of the wind chill readings.