2. Learn-in the Devices 

There  are  three  methods  to  learn  in  devices: 

command learning

local learning,

 and

 using 

Device  ID

. The system can learn a total of  20 

sensors.  All  learnt-in  devices  will  be  assigned 
to zone 1-20 sequentially. 

2.1. Command Learning 

Command Learning

:  

1. 

The  user  can  use  Commands  93-94  to 
learn devices into the system.

 

2. 

Command  93 

is  designed  to  learn  in 

devices  for  silent  reporting,  including 
WTR, Fall Sensor, or Panic Button. 

 

3. 

Command  93  &  94

  is  designed  to  learn 

in the following devices and sensors. 

 

 

PIR Sensor  ----- PIR 

 

Smoke Detector ---- SD 

 

Carbon Monoxide Detector---- CO 

 

Fixed Panic Button ---- PB 

 

Wrist Transmitter ---- WTR 

 

Pendant Transmitter ---- WTR 

 

Water Sensor ---- WS  

 

Fall Sensor ---- FS 

 

Carbon Dioxide Detector ---- CO2 

 

Temperature Sensor ---- TS 

Please  refer  to 

4.2  Programming  Your  1052-

QT-DT35A: Commands 93-94 

for details. 

The  PC  Programming  Tool  (1052-QT-DT35a-
Tool)  also  supports 

Command  Learning

Please  refer  to 

4.4  PC  Programming  Mode 

4.4.1.5 Device

 for detailed instructions. 

2.2. Local Learning 

Local Learning

:  

The  user  can  also  use  the  local  learning 
method to learn in all devices.  

1. When  the  device  is  learnt  in  for  the  first 

time,  voice  prompt  will  prompt  the 
device/sensor name and “learned.” 

2. Within  3  minutes  after  exiting  learning 

mode,  the  control  panel  will  emit  1  long 
beep everytime it receives a test code (from 
any device). 

To enter Local Learning Mode: 

1. Press  and  hold  the  Learn  Button  of  the 

CTC-1052-QT-DT35A.  When  pressed,  the 
CTC-1052-QT-DT35A  will  emit  one  beep 
sound initially, and then emit a double beep 
on  the  6

th

  second  followed  by  a  voice 

prompt 

“Release  the  button.”  Release  the 

Learn  Button  right  after  the  double  beep 
and the voice prompt. 

2. CTC-1052-QT-DT35A  will  enter  learning 

mode  as  it  plays  the  voice  prompt 

“Ready 

to  learn  sensor,  Press  sensor  buton

”.  The 

Purple backlight will turn on.  

3. Press  the  (Learn)  button  on  the  device  or 

sensor. 

Voice  Prompt:  “(Name  of  Sensor) 

learned.” 

4. If  no  action  within  10  seconds  after  voice 

prompt 

“Ready  to  learn  sensor,  Press 

sensor  buton

”.,  CTC-1052-QT-DT35A  will 

prompt  “Press  sensor  button.”  This  prompt 
will repeat two times if no action. 

5. 

If  no  action  after  second  “Press  sensor 
button”  prompt,  CTC-1052  will  prompt 
“Press  the  button  to  exit.”  This  prompt  will 
be  repeated  three  times  if  no  action 
continutes. 

6. If  no  action  (no  device  button  is  pressed) 

after  5  minutes,  the  CTC-1052-QT-DT35A 
will  automatically  exit  Local  Learning  Mode 
and return to idle mode. 

Voice Prompt: “We 

are now in Normal Operation Mode.” 

2.3. Learn-In Device using 
Device ID 

 

If  sensor  device  ID  is  given  (please  consult 
the supplier), the users can learn the device 
into the Control Panel using device ID. 

 

User  can  use  SMS  commands  or  the 
programming  tool  SMS  iWizard  (sold 
separately) to learn devices using device ID. 

 

Please  refer  to  the  table 

CTC-1052-QT-

DT35A 

SMS 

Remote 

Programming 

Command  Table

  or  the  SMS  iWizard 

operation manual on how to learn in devices 
into different zones using device ID. 

 

 

 

 

Summary of Contents for CTC-1052-QT-DT35A

Page 1: ...CTC 1052 QT DT35A User Manual Sep 4 2020...

Page 2: ...____________________________4 3 Remove the Devices 5 3 1 Command Removing ______________________________________________________5 3 2 Local Removing ___________________________________________________...

Page 3: ...thod 42 5 2 4 Report Sequence 43 5 3 Walk Test Range Test ____________________________________________________44 5 3 1 In Learning Mode 44 5 3 2 In Walk Test Mode 44 5 3 3 In Idle Mode 44 5 4 Global T...

Page 4: ......

Page 5: ...ing During or at the end of conversation press once to terminate two way voice communication 4 Microphone 5 Cellular Signal Strength Indicator 6 Orange LED Off Normal Cellular Network connection On Ce...

Page 6: ...propriate AC voltage rating to prevent component damage A DC 12V output and 1 5A switching power adapter is generally used to power CTC 1052 QT DT35A In addition to the adapter there is a rechargeable...

Page 7: ...e and Local Firmware Update cable CTC 1052 QT DT35A has a QT cable A for PC programming and a QT cable B for Local firmware update optional items sold separately To perform PC programming the QT cable...

Page 8: ...e 1 Press and hold the Learn Button of the CTC 1052 QT DT35A When pressed the CTC 1052 QT DT35A will emit one beep sound initially and then emit a double beep on the 6th second followed by a voice pro...

Page 9: ...ote Programming Mode SMS programming and PC Programming Mode 4 1 Remote Programming Mode To allow Remote Programming there are two options for CTC 1052 QT DT35A to answer the incoming calls 1 Auto Ans...

Page 10: ...ogramming phone set Short beep Command succeeded Long beep Command failed 4 Function Selection According to different Command you will have different entering in this part e g Tel Number Account numbe...

Page 11: ...p enter telephone number followed by You can hear one beep from the telephone speaker that indicates the programming is successful If you hear CTC 1052 QT DT35A emit one beep instead that means the pr...

Page 12: ...4th Tel s 124 1st 3rd 4th Tel s 134 2nd 3rd 4th Tel s 234 1st 2nd 3rd 4th Tel s 1234 1st 2nd 3rd 4th Tel 5th GPRS s 12345 1st 2nd 3rd 4th Tel 5th 6th GPRS s 123456 NOTE The Tel number selected in Comm...

Page 13: ...but call recipient can press DTMF keys to open two way communication or change modes If any of SMS Reporting Methods is selected Once alarm or emergency data is successfully transmitted the CTC 1052...

Page 14: ...is set as 1 OFF Command 37 AC Fault Report The CTC 1052 QT DT35A can be programmed to send a Fault Report when an AC power failure is detected Function Selection Result 0 OFF Send No Report 1 ON Send...

Page 15: ...uto answer incoming phone calls after a pre set number of rings have been reached The number of rings range from 00 no auto answer to 32 rings Function Selection Result 00 OFF 01 32 ON Factory Default...

Page 16: ...3 Only workable by entering 2 digits When Mobility Timer expires and no reset signal is received CTC 1052 QT DT35A will start to emit one long beep every 5 minutes to alert the user After 30 minutes i...

Page 17: ...to enable system Supervision function Once enabled CTC 1052 QT DT35A will be able to receive the check in signals from Wrist Pendants WTR to indicate their proper functioning Function Selection Resul...

Page 18: ...ection Result 0000 9999 0 9999 ppm Factory Default is set as 0800 800ppm Command 63 Speaker Volume Adjustment This function is used to adjust speaker volume To set speaker volume in different communic...

Page 19: ...riggered by a fall detection it can be cancelled within the Guard Time Delay by pressing the Active Button of the Fall Sensor for 4 seconds Function Selection Result 00 INSTANT REPORTING 01 99 DELAY F...

Page 20: ...tomatically returns to Programming mode Step 3 CTC 1052 QT DT35A will emit 2 beeps to indicate that Silent Pendant is learnt in successfully Adding a device for a second time is prohibited unless it i...

Page 21: ...eturned to its default value and all the devices that have been learnt in are removed You have to do the programming and learn in the device one by one again Command 99 Exit Programming Mode Enter 99...

Page 22: ...4 5 GPRS1 6 GPRS2 1234 06 Telephone number for status report STARP PROG 8744 STARP 1234 To select then number for status report 1 Telephone 1 2 Telephone 2 3 Telephone 3 4 Telephone 4 5 GPRS1 6 GPRS2...

Page 23: ...Silent mode On 1 Silent mode Off 1 Silent mode Off 37 AC fault report ACRPT PROG 8744 ACRPT 1 To enable disable AC fault report 0 Disable 1 Enable 1 Enable 38 Follow On Call Back FOLON PROG 8744 FOLO...

Page 24: ...me for fall sensor FAGUD PROG 8744 FAGUD 15 To set the guard time delay time for fall sensor 00 Instant 01 99 1 99 seconds 15 sec 77 Speech report ack SPACK PROG 8744 SPACK 1 Speech report acknowledge...

Page 25: ...65536 Example PROG 8744 FWURL HTTP 59 1 2 3 53000 hfs_server 52dtab04a bin 63488 Add a voice prompt V1URL PROG 8744 V1URL URL File_Name Account To add a voice prompt URL Domain Name File_Name XX For o...

Page 26: ...to power supply Press the power button to power on the panel Step 2 Plug the PC Programming cable into the Programming Telephone Jack of the panel Step 3 Connect the PC Programming cable to the USB E...

Page 27: ...2 QT DT35a Tool programming software open your browser and type below URL in the address bar https www climax com tw climax download 1052qt dt35a html Step 7 1052 QT DT35a Tool is a portable applicati...

Page 28: ...DT35A after installing the USB Driver the USB port connected to CTC 1052 QT DT35A enter the password default 8744 and then click Open Step 9 A Read All command success message will pop up Click OK an...

Page 29: ...reporting method for each Tel Number 1st 4th Tel by selecting from each drop down menu respectively Available reporting methods include Speech and SMS CID 05 To select the number for alarm report Sel...

Page 30: ...1st 4th Tel numbers for reporting The account number s for the 1st 4th Tel numbers can also be programmed in this tab 01 04 Telephone Number Programming 01 04 Used to program the 1st 4th Tel numbers r...

Page 31: ...ode is On all normal operation warning beeps guard time tone key tone and rings will be silenced Speech Reporting made under Silent Mode will automatically be switched to Listen in but call recipient...

Page 32: ...designed for any compatible sensor except Fall Sensor fall detection The delay time can range from 00 instant reporting to 99 seconds Emergency alarms activated by Smoke Detectors SD Carbon Monoxide...

Page 33: ...er the value the louder the voice 64 Set Microphone Sensitivity To set the microphone sensitivity with a number ranging 1 to 5 This value represents the received sound source range The higher the valu...

Page 34: ...a Silent Device it will not sound any warning beeps during Reporting and Guard time period 94 Learn In Device This is used for learning in non silent devices The available devices that can be learnt i...

Page 35: ...al reception range of CTC 1052 QT DT35A If no signal is received within 20 sec a Learning Fail message will pop up and CTC 1052 QT DT35A will automatically return to Programming mode Adding a Device f...

Page 36: ...ve Zone 1 Device command success will pop up 82 Remove Zone 2 Device Click Remove to remove zone 2 device from CTC 1052 QT DT35A A message Remove Zone 2 Device command success will pop up 4 4 1 6 Call...

Page 37: ...52 QT DT35A will instantly pick up any call that has 321 as the last 3 digits If a number string 17605851848 is programmed CTC 1052 QT DT35A will instantly pick up any call that has 7605851848 as the...

Page 38: ...ahrenheit 32 F 212 F Factory Default is 47 F 4 4 1 8 CO2 The CO2 tab allows user to program the CO2 Alarm Reporting threshold When CO2 concentration value reaches or exceeds the Alarm Reporting thresh...

Page 39: ...different tabs will show the current values of each setting If you select a different profile from the drop down menu the Current Setting profile will disappear to indicate the 1052 QT Tool is no long...

Page 40: ...with a different name by clicking Save Profile As A pop up window will prompt you to enter the new profile name After entering the profile name and clicking OK the new profile will be saved Apply pro...

Page 41: ...ase see pictures below as examples When you use another computer to execute the 1052 QT Tool and you wish to apply the configurations of the profiles you created on the old computer please make sure t...

Page 42: ...20 Auto Answer Numbers If a user calls the Control Panel using an auto answer number the Control Panel will pick up the call and instantly open up a two way communication with the caller The Control P...

Page 43: ...s CTC 1052 QT DT35A will emit a voice prompt reminder Inactivity timer expiring please reset every 5 minutes to notify the user for 30 minutes When the Mobility timer is not reset after 30 minutes CTC...

Page 44: ...8 3 C the panel will send Low Temperature Restore report to CMS 5 2 Alarm Activation When an alarm is triggered CTC 1052 QT DT35A will enter the Guard Time Delay period see Command 42 The Help Button...

Page 45: ...service provider for your GPRS username If no username is required you may skip this step Password offered by your SIM card service provider Please inquire your service provider for your GPRS password...

Page 46: ...s adjusted the adjusted value will be kept for the next communication Press any DTMF key except the designated hang up keys to reset the communication time to its preset duration Please note that when...

Page 47: ...will try one report destination for a maximum of 4 times 2 Control Panel will try all report destinations for up to 15 times in total 3 If more than 1 report destinations are set to a report method e...

Page 48: ...to your desirable location in the house and press the TEST button of the device to observe the range of its operation Step 3 If CTC 1052 QT DT35A responds with one long beep then the particular device...

Page 49: ...vices one by one again 6 Appendix 6 1 CID Event Code The message composition for CID Event code is in the form ACCT MT QXYZ GG C1C2C3 And is explained in the following table 100 Panel emergency When H...

Page 50: ...R learned in previously NOTE This event code will be sent with a fixed zone number of 072 339 Medication Non Adherence When the scheduled dose is still not taken after Time for Medicine alarm expires...

Page 51: ...47 Mobility Timer Expired reporting NOTE This event code will be sent with a fixed zone number of 071...

Page 52: ...igits Bi No account number 11 Bi 4 or 6 or 8 digits Account number 1 Tel Number 1 Bi No account number 12 Bi 4 or 6 or 8 digits Account number 2 Tel Number 2 Bi No account number 13 Bi 4 or 6 or 8 dig...

Page 53: ...Bi 95 F 56 Bi Low Temperature Reporting Threshold 032 200 F Bi 47 F 57 Bi CO2 Alarm Reporting Threshold 0 9999ppm Bi 800ppm 63 Bi Set Speaker Volume Enter Mode Number Speaker Volume Note Mode Number 1...

Page 54: ...nt into the Control Panel Door Sensor Played once when the sensor has been learnt into the Control Panel Water Leak Sensor Played once when the sensor has been learnt into the Control Panel Emergency...

Page 55: ...e received including interference that may cause undesired operation 3 This device should be installed and operated with a minimum distance of 20 centimeters between the radiator and your body 4 The a...

Reviews: