9
Commands (
20-24
) are used to program
the Alarm reporting method for each Tel.
Number.
Command (
20
):
Program the same Alarm
Reporting Method for
all
4 Tel. Numbers.
Command (
21-24
): Program the alarm
reporting method for the 1
st
-
4
th
Tel.
Numbers
respectively.
Available Options:
<NOTE>
The latest Command (
20-24
) setting(s)
will overwrite any previously entered
setting(s).
If Speech Method is selected:
After the dialing for alarm/emergency
trigger is successful, CTC-1052-QT-
DT35A opens a two-way voice
communication between the Call
Recipient and CTC-1052-QT-DT35A for
1-10 minutes (set by Command #46).
If the Call Recipient needs more talk
time, they can press any keys except 9
or 0 on their phone set to reset to the
original communication duration (set by
Command #46).
To terminate the call, press (
9)
or
RESET BUTTON on CTC-1052-QT-
DT35A.
During the Speech period, CTC-1052-
QT-DT35A will emit two beeps via the
telephone handset to alert the call
recipient the remaining time of 20 & 10
secs.
Speech Reporting made under Silent
Mode (set by Command #35) will
automatically be switched to Listen-in,
but call recipient can press DTMF keys
to open two-way communication or
change modes.
If any of SMS Reporting Methods is
selected:
Once alarm or emergency data is
successfully transmitted, the CTC-
1052-QT-DT35A will automatically send
out a SMS (CID) Message.
Command 31
Ringer Enable for Incoming Calls
CTC-1052-QT-DT35A can be programmed
to emit a ring tone as an audio alert, or
silent for incoming calls.
Function Selection
Result
(0)
OFF
(Ring Tone Disable)
(1)
ON
(Ring Tone Enable)
Factory Default
is set as (
0
),
OFF
.
If the function is set to
ON
, you can answer
the incoming call by pressing the
Active
button
of WTR, PB, or Fall Sensor, or the
Help Button
on CTC-1052-QT-DT35A.
The time-out period for the incoming call is
30 minutes.
To terminate the incoming call, either press
the
Active button
of WTR, PB, or Fall
Sensor, or press the
Reset Button
on
CTC-1052-QT-DT35A.
During the AC Power failure period, Ring
Tone is automatically disabled.
Command 32
Audible Fault Alert
CTC-1052-QT-DT35A can be programmed
to emit Fault Alert Beeps
every 30
seconds
from AC Failure.
Function Selection
Result
(0)
OFF
(No Warning Beep)
(1)
ON
(With Warning Beep)
Factory Default
is
set as (
0
),
OFF
.
Command 34
Method
Function
Selection
Speech
Method
(3)
Open Two-way
communication
SMS
Reporting
Method
(4)
SMS (CID)
Summary of Contents for CTC-1052-QT-DT35A
Page 1: ...CTC 1052 QT DT35A User Manual Sep 4 2020...