![Climax BF-R Operating Manual Download Page 31](http://html1.mh-extra.com/html/climax/bf-r/bf-r_operating-manual_2624900031.webp)
P/N 102823, Rev. 0
Page 19
5. Rotate the collar 180
degrees (see Figure 3-3).
6. Position the alignment
guide on the collet/wedge
shaft so that there is enough
travel for the collet/wedges.
7. Lock the alignment gauge
onto the collet/wedge shaft
with the set screw on the
lock collar.
8. Remove the cotter pin from
the tip of the collet/wedge
draw rod (see Figure 3-4).
T
ABLE
3-3. C
OLLAR
ROTATED
AND
SLOTS
OPPOSITE
IDENTIFICATION
Number
Component
1
Slots opposite each other
2
Set screw
SLOTS OPPOSITE
EACH OTHER
SET SCREW
2
1
F
IGURE
3-3. C
OLLAR
ROTATED
AND
SLOTS
OPPOSITE
EACH
OTHER
Summary of Contents for BF-R
Page 1: ...BF R FLANGE FACER OPERATING MANUAL ORIGINAL INSTRUCTIONS P N 102823 January 2022 Revision 0...
Page 2: ......
Page 4: ...Page B BF R Operating Manual CLIMAX GLOBAL LOCATIONS...
Page 5: ...P N 102823 Rev 0 Page C CE DOCUMENTATION...
Page 10: ...Page iv BF R Operating Manual This page intentionally left blank...
Page 12: ...Page vi BF R Operating Manual This page intentionally left blank...
Page 34: ...Page 22 BF R Operating Manual This page intentionally left blank...
Page 48: ...Page 36 BF R Operating Manual This page intentionally left blank...
Page 64: ...Page 52 BF R Operating Manual This page intentionally left blank...
Page 65: ...P N 102823 Rev 0 Page 53 APPENDIX B SDS Contact CLIMAX for the current Safety Data Sheets...
Page 66: ...Page 54 BF R Operating Manual This page intentionally left blank...
Page 67: ......
Page 68: ......