background image

 

Step 3.    The tag is cleared. You can apply the tag to the Keypad Tag sensor zone to check if the Keypad will emit 4 beeps 

to indicate error.   

 

Mounting Remote Keypad   

To mount the remote keypad: 

I. 

Remove the front cover. 

II.  Using the 2 mounting holes of the back cover as a template, mark off the positions in the most appropriate place. 
III.  Insert the wall plugs if fixing into plaster or brick surface. 
IV.  Screw the Remote keypad onto the wall plugs.   
V.  Replace the front cover. 

 

How to Set System Mode 

You may choose to arm/home arm with or without a Control Panel User Code. Disarm always requires a Control Panel User 
Code. 

Arm/Home without Control Panel User Code 

 

In the Test mode, Pressing 

  key and then 8 key to enable Arm/ Home without Control Panel User Code function, then exit 

Test mode by pressing the # key twice. 

 

Enter Arm Mode

: Press      key. If panel has no fault and arming is successful, the Red LED will turn ON with a 

short beep. When successful Arm, Red LED flashes, Backlight turns on with a long beep. 

 

Enter Home Mode

: Press      key. If panel has no fault and arming is successful, the Orange LED will turn ON with 

a short beep. When successful Home Arm, Orange LED  flashes,  Backlight  turns on  with  a 
long beep. 

 

Return to Disarm Mode

: Enter Control Panel User Code or put Tag on the Keypad Sensor will emit a short beep. 

If disarm is successful, Backlight flashes along with 2 beeps.   

 

Arm/Home with Control Panel User Code or NFC Tag

 

In the Test mode, Pressing 

  key and then 9 key can enable Arm/ Home with User Code function, then exit Test mode by 

pressing the # key twice. 

(Default) 

This function must be enabled for NFC tag to be used.

 

 

Enter Arm Mode

: Press 

    

then enter Control Panel User Code (or apply Tag to tag sensor zone), Red LED light 

turns on along with a short beep. If panel has no fault and arming is successful, the Red LED 
will flash, Backlight turns on along with a long beep.   

 

Enter Home Mode

: Press 

    

then enter Control Panel User Code (or apply Tag to tag sensor zone), Orange LED 

light turns on along with a short beep.  If panel has no fault and arming is successful,  the 
Orange LED will flash and Backlight turns on along with a long beep.   

 

Return to Disarm Mode

:

 

Enter Control Panel User Code or put tag on the Keypad Sensor along with a short beep 

If disarm is successful,

 

Backlight flashes along with 2 beeps.

   

 

Check System Mode 

When keypad is in standby mode, you can press the 

  key to check current system mode of the panel. 

 

If system is in Arm Mode, the Keypad red LED will flash once, and white backlight will turn on with a long beep. 

 

If system is in Home Mode, the Keypad orange LED will flash once, and white backlight will turn on with a long beep.     

 

If system is in Disarm Mode, the Keypad white backlight will flash once with two beeps. 

 

Clear Alarm Memory 

When keypad is in standby mode, you can press the # key to delete the alarm memory, the keypad will then emit one beep. 

 

Dual-key Alarm function   

The Dual Key function allows you to activate alarm from Keypad by pressing 2 keys at the same time. Press and hold both 
key for 1 second to transmit signal, the Keypad will emit a long beep to confirm. The dual-key function is 

disabled

 by default. 

To enable it, please refer to the Test Mode section.   

 

                                                                               

     

 

Summary of Contents for KPT-32

Page 1: ...successful command 4 continuous beeps will sound indicating mistake and the user should repeat the process again Backlight will be ON for any key pressed or command sent from the Keypad LED Indicator Red LED Away Arm Key Red LED on the system is in Test Mode Red LED Red flashes and Backlight on in the Away Arm Mode Red LED flash with 4 beeps failure due to the following reasons No response from th...

Page 2: ...eypad returns to Stand by mode NOTE You can also when Idle Supervisory Signal The Remote Keypad will automatically transmit Supervisory Signals periodically to the Control Panel at random intervals of 15 18 minutes Test Mode Remote keypad can be put into Test mode by entering the Keypad PIN code default 0000 followed by key along with a long beep sounding the Red LED and backlight will turn on To ...

Page 3: ...ange Keypad area setting 2 Put the Control Panel into Learning Mode 3 Press and hold and key of keypad for 2 seconds to transmit learn code to Control Panel 4 The keypad will be displayed under learned device Area update is complete Tamper Protection The keypad is protected against any attempt to open the lid or to detach keypad from its mounting surface Tamper protection is disabled when the keyp...

Page 4: ...User Code function then exit Test mode by pressing the key twice Default This function must be enabled for NFC tag to be used Enter Arm Mode Press then enter Control Panel User Code or apply Tag to tag sensor zone Red LED light turns on along with a short beep If panel has no fault and arming is successful the Red LED will flash Backlight turns on along with a long beep Enter Home Mode Press then ...

Page 5: ...lashes for 3 seconds along with 4 beeps to indicate transmission error c If sent Arm Home Disarm signal but have no response from the Control Panel the Red LED flashes Orange LED flashes for 3 seconds along with 4 beeps d When incorrect Keypad PIN code is entered to enter Test mode The Keypad will emit 4 beeps If incorrect Keypad PIN codes are entered for 4 times the Keypad will disable key input ...

Page 6: ...is connected Consult the dealer or an experienced radio TV technician for help FCC Caution To assure continued compliance any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate this equipment Example use only shielded interface cables when connecting to computer or peripheral devices FCC Radiation Exposure Statement Th...

Reviews: