The 642 LCD Keypad includes a programmable 32-character LCD screen, keypad zone, and supports the Paradox Memory Key. All of the
LCD keypad’s features and options can only be accessed through the keypad’s programming mode.

[1] LABELS

This option allows you to program some of the messages that appear on the keypad’s LCD screen. After entering Keypad Programming Mode,
select option [1]. Enter the three-digit section that corresponds to the message you wish to change.

[101] to [124] = Zone 1 to Zone 24
[125]

= Partition A

[126]

= Partition B

[127]

= Partition A & B

[201] to [208] = Notes

Table 1: Character Reference

[2] KEYPAD OPTIONS

After entering Keypad Programming Mode, select option [2]. Press the corresponding keys until all desired options are set, and then press

[

ENTER

].

Entering Keypad Programming Mode

STEP 1: Press and hold the

[

ENTER

]

key.

.

STEP 2: Enter the [

KEYPAD CODE

]Default:

0000

STEP 3: Press the key corresponding to the desired option or use the

[

s

] [

t

]

keys

to scroll through the available options and press

[

ENTER

]

.

[

1

= Labels

[

4

= Read Key [

7

= Set Day

[

2

= Options

[

5

= Write Key [

8

= Set Language

[

3

= Keypad Code

[

6

= Set Time

[

9

= Keypad Lock

Key

[UC] Mode

[LC] Mode

[SP] Mode

X1

X2

X3

X4

X1

X2

X3

X4

X1

X2

X3

X4

[1]

A

B

C

1

a

b

c

-

Û

Ù

Ú

Ü

[2]

D

E

F

2

d

e

f

&

û

ù

ú

Ô

[3]

G

H

I

3

g

h

i

*

Ò

Ó

o

ô

[4]

J

K

L

4

j

k

l

(

ò

ó

ö

¿

[5]

M

N

O

5

m

n

o

)

Ê

È

É

Ë

[6]

P

Q

R

6

p

q

r

[

ê

è

é

ë

[7]

S

T

U

7

s

t

u

]

Å

Ä

å

â

[8]

V

W

X

8

v

w

x

>

à

á

ä

A

[9]

space

Y

Z

9

space

y

z

<

a

Î

Ì

Í

[0]

@

!

=

0

{

}

0

ï

i

Ñ

ñ

Key

Description

OFF

ON

[1]

Keypad Zone

Disabled

Enabled

[2]

Keypad Zone Requires 1k

EOL Resistor

No

Yes

[3]

Keypad Zone Set to

Zone A

Zone B

[4]

Keypad Zone Supervision

Disabled

Enabled

[5]

Keypad Tamper Supervision

Disabled

Enabled

[6]

Partitioning (Enable this option if the system is partitioned)

Disabled

Enabled

[7]

Master/Slave (See “Slave/Master Option” on page 2)

Master

Slave

[8]

Arming Display for systems that support

Less than 12 zones

More than 12 zones

[9]

Multiple Zone Display (status of several zones on one screen without zone label)

Disabled

Enabled

[Arm] = A

Scrolling Zone Display (each screen displays zone label and status of one zone)

Disabled

Enabled

[Stay] = B

Keypad Clock Mode

Refreshed by Panel

Stand alone

[Force] = C

Display AC status on LCD screen
Note: It is recommended that you turn on the option (No) for the 748/748ES pan-
els since they do not support this function.

 

Yes

No