When the items are consigned by the carrier
, check that
the packaging and the unit are undamaged.
If damage or missing components are noted, indicate this on
the delivery note. A formal complaint should be sent via fax
or registered post to the After Sales Department within eight
days from the date of receipt of the items.
The units are supplied complete with:
- instruction manual;
- guarantee certificate;
- CE declaration;
- list of the main components and sub-assemblies fitted on
the product. These are contained in a plastic bag (A)
attached to the top of the chiller.
The unit must be handled by qualified and suitably equipped
personnel only using equipment appropriate for the weight
of the unit, in compliance with the safety standards in force
(and subsequent amendments.).
If a forklift truck is used, insert the forks under the base,
spacing the forks as wide apart as possible.
If a crane is used, pass the cables through the bottom of the
base, making sure they do not exert pressure on the unit.
Once the packaging has been removed, the appliance can
be lifted and moved by inserting two metal tubes (max.
diameter 22 mm) into the feet, and using suitable handling
equipment.
The instruction manual
is an integral part of the unit
and should therefore be read and kept carefully..
The packaging should not
be removed until the unit is
located in the installation site.
Do not dispose
of packaging materials in the environ-
ment or leave them within reach of children as they may
represent a hazard.
The weight of the unit
is biased towards the compres-
sor side (side of the packaging with the bar code, see
the figure).
During transport
, the unit should be kept in a vertical
position.
The unit must be stored sheltered from direct sunlight,
rain, wind or sand.
Avoid exposing the unit to direct sunlight, as the pres-
sure inside the refrigerant circuit may reach dangerous
values and cause the activation of the safety valves,
where fitted.
Check the instructions on the packaging for stacking
units.
The packaging must be removed by the operator using
suitable protective equipment (gloves, glasses, etc.).
Take special care not to damage the unit.
Observe the local standards in force as regards disposal
of the packaging, using specialist collection or recycling
centres.
RECEIVING AND HANDLING THE PRODUCT
I A
4
AWR MTD - AWR MTD/B
GB 01/2009
Hole Ø22
A
H
P
L
Bar code
(compressor side)
Dimensions AWR
0011
0025
0031
0041
0051
0061
Dimension L
mm
970
970
970
970
970
970
Dimension P
mm
475
525
525
525
525
525
Dimension H
mm
1150
1450
1450
1450
1600
1600
Gross weight
kg
135
160
165
175
185
190