Keypad Control Panel Operation
1.
Keypad Control Panel
1.
Digital Display:
•
Time remaining in minutes and seconds from
00:00
to
99:50
when at temperature in Timed
mode or
when the timer is being set.
•
PAUSE
when in Timed mode but below
cooking
temperature, or the door is open,
and
the timer has
been started.
•
CooL
when in the Steam and Hold mode
below
temperature and the timer not started.
•
HoLd
when in Hold mode.
•
Cont
when at temperature in Continuous
Steam
mode.
•
CooL
flashes when below temperature in
Continuous
Steam mode.
•
The
temperature
when the
DISPLAY TEMP
key is
pressed.
•
Addh2o
when the water level is below the
water
sensor.
2.
3.
Number Pad Keys:
These keys set the number
of
minutes and seconds in the timer count down.
Pressing
the number keys 1 2 3 4 in this
sequence, sets the timer
for 12 minutes and 34
seconds (12:34).
START/STOP Key:
This key starts and stops the
timer.
In TIMED mode the steaming functions are
linked to the
timer. In MANUAL mode, the
steaming functions are
independent of the timer.
4.
CLEAR Key:
This key resets the timer to zero
(00:00) after it has been stopped. The timer must
be
zeroed by pressing this key before a new time
can be set.
5.
TIMED/MANUAL Switch:
The TIMED/MANUAL
switch
selects the manual or timed operating
mode.
•
Pressing the MANUAL end of the switch
selects the
manual mode, and lights the red
indicator built into
the manual end of the
switch.(See also the Note at
the bottom of this
page)
•
Pressing the TIMED end of the switch selects
the
timed mode.
6.
ON/OFF switch
–
Controls the electric power to
the
appliance.
•
Pressing the ON (top) end of the switch
energizes the
steamer control panel.
•
A red indicator on the switch lights, and the
steamer
begins to heat-up.
•
Pressing the OFF (bottom) end of the switch
turns
the
steamer control panel OFF and the
indicator light
goes out.
7.
Hi Limit Reset Light
– If the high limit temperature is
reached, the red indicator light comes ON, an alarm
sounds,
the heating elements are turned OFF and the
control panel is
de-energizes. To reset the system, turn
the ON/OFF switch
OFF for 5 minutes and then back ON.