8
C. INSTALLATION OF THE COMBI
1. Selecting a Location for the Combi
a. For safe and efficient operation, observe the following criteria when selecting an operating location
for a Combi
1)
Passages and doors must be high enough and wide enough for a Combi and its
pallet. See Table 2-1.
2) Location selected must be capable of supporting a Combi. See Table 2-1.
3) The area MUST be free from and clear of combustible materials.
4) KEEP THE COMBI AREA FREE AND CLEAR OF COMBUSTIBLES.
5) The operating surface must be level enough to allow leveling a Combi with its adjustable legs.
6) A
Combi
MUST
be level both front to back and side to side.
7) Position the Combi so it will not tip or slide.
8) The floor where the loading trolley rolls must be level and even.
9) Level the floor if needed. (Fig. 7).
10) The ambient temperature should be within 40° and 95° F.
11) Proper air supply for combustion and ventilation is REQUIRED for and CRITICAL to safe,
efficient operation of a Combi.
12)
Required Clearances:
Rear - 2", Left Side - 4". Right Side 2 1/2"
a) Allow for sufficient distance if a "high heat source" (i.e. Broiler) is located next to the unit
b) Allow for sufficient clearance on left side for service access (contact the factory service
department for recommendations)
c) Installation must comply with all local fire and health codes.
13) Do not install the Combi directly over a drain. Steam rising up out of the drain will adversely
affect operation, hamper cooling air circulation, and damage electrical and electronic
components.
14) Make sure the air vents of the Combi are not blocked.
TABLE 2-1 WEIGHTS AND DIMENSIONS INCLUDING PALLET AND CRATE
STEAM
GENERATOR
MODEL
INJECTOR
MODEL
WEIGHT
IN
POUNDS
WIDTH
IN
INCHES
DEPTH
IN
INCHES
HEIGHT
IN
INCHES
OEB-6.10 OES-6.10
375
38
36
40
OEB-6.20 OES-6.20
485
47
45
42
OEB-10.10 OES-10.10
475
38
37
50
OEB-10.20 OES-10.20
540
47
45
50
OEB-12.20 OES-12.20
717*
48
46
64
OEB-20.10 OES-20.10
750*
40
38
85
OEB-20.20 OES-20.20
970*
52
46
85
* = including Loading Trolley