Cleveland Convotherm OEB-10.10 Installation And Maintenance Instructions Manual Download Page 1

Part No. COMBI-OE-INM REV. A, 8/05 

Installation Manual 

 

Installation and Maintenance Instructions 

 

CONVOTHERM BY CLEVELAND 

COMBI ELECTRIC MODELS 

 

 

 
 
 
 
                                                                                                           
 
 

  1333 East 179

th

 Street 

  Cleveland, Ohio 44110 

 

Phone: (216) 481-4900 

Fax: (216) 481 3782

 

www.clevelandrange.com

Summary of Contents for Convotherm OEB-10.10

Page 1: ...REV A 8 05 Installation Manual Installation and Maintenance Instructions CONVOTHERM BY CLEVELAND COMBI ELECTRIC MODELS 1333 East 179th Street Cleveland Ohio 44110 Phone 216 481 4900 Fax 216 481 3782 w...

Page 2: ...rors DO NOT OPERATE OR ATTEMPT TO OPERATE THIS APPLIANCE OR ANY ACCESSORIES WITHOUT READING COMPLETELY AND FULLY UNDERSTANDING THIS MANUAL FOR YOUR SAFETY Do not store or use gasoline or other flammab...

Page 3: ...nd it is the responsibility of the owner and installer to comply with these codes Cleveland Range equipment is built to comply with applicable standards for manufacturers including UL ANSI NSF ASME Nt...

Page 4: ......

Page 5: ...representative will present and explain your free copy of the Cleveland Range Use and Care Video Combi video release expected in September 2005 Consult your Customer Service Directory or call Clevelan...

Page 6: ...ES CONNECTIONS 9 Install Electric Power Lines 9 Electrical Connection Data 10 Install Water Supply 11 Install Free Air Vented Drain Lines 14 Exhaust Hood Requirements 16 Moving a Combi to its Operatin...

Page 7: ...ntents that become liquid on oven racks higher than you can see into the containers Cover containers individual or on trolleys containing hot or hot liquid items to help prevent spills during transpor...

Page 8: ...ase provide the following information when you contact Cleveland Range or a qualified Cleveland Range authorized service representative Serial Number___________________________________________________...

Page 9: ...e following information Power Consumption Voltage Number of Phases Frequency Model Number Serial Number 10 Side Wall Removable for service by qualified Cleveland Range authorized service representativ...

Page 10: ...n temperature is continuously variable between 86 F and 482 F Retherm cooking mode 5 Oven temperature is continuously variable between 248 F and 320 F Start Stop 6 Start cooking modes cooking ideas an...

Page 11: ...lapsed cooking time when using Core Temperature mode Core Temperature 20 Set the nominal core temperature See the actual or nominal core temperature See the actual core temperature during cooking in t...

Page 12: ...hipping damage d If the Combi is damaged or damage is suspected 1 Inform your dealer at once 2 Inform Cleveland Range in writing within 3 days 3 Submit a Damage Claim to the shipper 4 General Safety a...

Page 13: ...from improper use or cleaning is NOT covered by warranty Damage from improper use or cleaning repair maintenance descaling and failure to use appropriate cleaning solutions is NOT covered by warranty...

Page 14: ...ion is REQUIRED for and CRITICAL to safe efficient operation of a Combi 12 Required Clearances Rear 2 Left Side 4 Right Side 2 1 2 a Allow for sufficient distance if a high heat source i e Broiler is...

Page 15: ...o make sure the Combi is compatible with the local electric supply c Note the rating plate is located on the left side of the Combi d Install a dedicated main disconnect switch and a separate fuse or...

Page 16: ...ires 3 Ground 3 Ground Wire Size Cu 90 C AWG 6 6 OEB OES 10 20 AND 12 20 Volts 208 240 Phase 3 3 Hz 60 60 Amps 77 3 88 3 Wires 3 Ground 3 Ground Wire Size Cu 90 C AWG 3 2 OEB OES 20 10 Volts 208 240 P...

Page 17: ...er quality install it BEFORE connecting the water supply lines to a Combi g If analysis shows that supply water is below Minimum Water Quality 1 EITHER a water treatment system and or carbon filter mu...

Page 18: ...old water supply splitter Order Number SPN or similar tee fitting must be at least next largest size of pipe than the connection provided at the Combi 7 If water supply fails to meet requirements show...

Page 19: ...COMBI Steam Generator or Injector Dehumidification Cleaning System Water Connection Pressure Reducer if required Main Water Shut Off Valve Main Cold Water Supply Air Water Column if required Condenser...

Page 20: ...to floor drain 4 Do not install a trap in the drain line d Free air venting requires minimum 1 clearance between the end of the drain line and the top of the floor drain e Do not connect the Combi dr...

Page 21: ...A NUMBER DESCRIPTION AND PART NUMBER 1 GASKET INTERNAL DRAIN TO ELBOW P N C6015406 2 ELBOW 87 P N C6015402 3 PIPE BELL END 50mm x 500mm 2 x 19 685 P N C6015403 4 ELBOW DRAIN CONNECTION P N C6015405 5...

Page 22: ...e hood including the Combi 2 If an existing hood cannot be used a new one must be constructed over the Combi 3 When determining hood size be sure to include Operating Clearances of 2 inches rear 24 in...

Page 23: ...ure 3 3 To lift units with a forklift low lift truck or hand truck place wooden spacers between the feet of the Combi Fig 3 4 Stay to the right of the Drain A and the Overflow B on Figure 3 See Table...

Page 24: ...ervice access contact the factory service department for recommendations c Installation must comply with all local fire and health codes j Keep the vents on the top and bottom of the Combi clear clean...

Page 25: ...19 Figure 6 Figure 4 7Figure 5...

Page 26: ...e 2 5 Installation Check List TASK REFERENCE COMPLETED Page No Preparation Check operating location clearances 16 17 Test supply water quality 11 Verify Exhaust Hood Requirements 16 Verify Electric Po...

Page 27: ...TIONAL TESTS DANGER Death severe electrical shock or equipment damage can result from touching any component inside a Combi when the main external power switch is in the ON position Use extreme cautio...

Page 28: ...e operating Note Remove the plastic cover from the tip of the Temperature Probe before starting the Combi 1 After initial installation check a Suction Plate Hinged Fan Guard for both swing and latch a...

Page 29: ...ial 6019002_00 D 6 Pausing on a tone icon will cause it to sound 7 Select a signal tone by pausing on it 8 Confirm with Smart Key d Set Volume 1 Start Setup Procedure Above 2 Select Volume speaker and...

Page 30: ...s 1 99 7 Confirm with Smart Key i Program Protection 1 Compatible connected energy optimization equipment is required to use this option 2 Connecting the unit to an energy optimization unit during pow...

Page 31: ...ning i STEAM GENERATOR Models The heating element for the oven heat exchanger and the heating element for the steam generator turn on and the program runs j ALL MODELS the program in step 1 will run k...

Page 32: ...starting this process b Before starting remove large pieces food or cooking residue from the oven chamber This will help prevent the drain from becoming blocked c Check the level of CONVOTHERM by Clev...

Page 33: ...to 350 F in any cooking mode d Set Probe Temperature to 210 F e Begin cooking program f Display shows set nominal temperature on the left and probe temperature on the right g Press Temperature to disp...

Page 34: ...alfunctions occur while a Combi Oven Steamer is operating The tables show possible causes and their remedies WARNING If the Burner or Electric Heating ON icon and the Cooking Mode Engaged icon are lit...

Page 35: ...bi to cold water restart Solenoid valve dirt filter contaminated Remove and clean filter Solenoid valve fault Call customer service E15 E25 Excess temp of condenser condenser sensor failure Condenser...

Page 36: ...ocked Clean steam measurement line see Daily servicing and maintenance Water sprays from air outlet when door is closed Combi drain blocked Clean outflow Water sprayed out of steam generator into oven...

Page 37: ...ress the Start Stop key to confirm the error 3 The modes which can be selected will be indicated by flashing 4 Proceed as normal 5 Select a program by pressing the corresponding key Note locked progra...

Page 38: ...ection area temp too high X X X X X up to 284 F up to 284 F up to 284 F up to 284 F up to 284 F E03 Fan malfunction X X up to 212 F 1 E04 Connection area fan malfunction X X X X X up to 284 F up to 28...

Page 39: ...ator heater X X X X X X X E 29 Error in ground connection E33 Steam generator heater error X 1 X 1 X 2 X 2 X 1 2 X 1 2 X X 1 2 X X E34 Steam generator pump error X X X X X X X X X X E80 ID error E81 P...