2. Burner Ignition Test (Lighting and Shutdown Instructions)
It is recommended that this test be performed before beginning the Startup Test Procedure. This will
insure that the basic heating system is operating normally before reviewing the overall operation of
the steamer, since much of the operation is dependant on the operation of the burner control system.
a. Lighting
Instructions
This is a functional test of the intermittent pilot ignition system. Pilot/burner ignition is completely
automatic.
NOTE: Each compartment has its own steam generator and control system, and must be started
independently.
1). If not already done during prior installation or testing:
·
Test the water supply lines.
·
Leak test the gas supply lines.
·
Check that the ON/OFF valve of the automatic gas control valve is in the ON position.
·
Turn the Main Manual gas valve to the open position.
2). The controls should be set as follows:
·
The main power switch should be in the OFF position.
·
The steamer’s ON/OFF levers/switches should be set to the OFF position.
·
The MANUAL/TIMED switches should be set to the TIMED position.
3). Turn ON the electrical power to the steamer at the main power switch.
NOTE:
When initial power is supplied to the steamer with the ON/OFF lever/switch in the
OFF position, a 3-minute blowdown cycle starts. This blowdown cycle stops
when the 3 minutes have elapsed or the ON/OFF lever/switch is changed to the
ON position.
4). Turn ON the electrical power to the steamer at the ON/OFF levers/switches.
a) The red indicator lights in the control panel light and water begins filling the steam
generator. The pilot/burners do not light until water reaches the safety level in the probe
assembly.
WARNING
DO NOT TRY TO LIGHT THE BURNERS OR PILOT WITH A FLAME.
The Gemini has an electronic ignition system, which automatically lights the
pilot and burners, senses the flame, and controls gas flow. This provides
precise burner control, safety ignition, and shutdown features.
DEATH, INJURY OR EQUIPMENT DAMAGE may result from an improperly
adjusted gas control and ignition system. Do not alter any adjustments on this
electronic control or automatic gas valve.
If adjustment is required, contact an authorized service center. Cleveland
Range is in no way responsible for the operation or safety of this equipment if
the controller, valve or igniter probe is adjusted by anyone other than a
Cleveland Range authorized service representative.