AC POWER CORD HOOKUP
6 of 18
A800-7425 J
Figure 4
USE
CMC P/N
DESCRIPTION
Transducer X43-06825
5 Pin Connector
Cable
MS-3106A-14S-5P
X43-06928
Clamp and Bushing
Amphenol 97-3057-1007-1
Tension
X43-07181
3 Pin Connector
Output
MS-3106A-14S-7P
Signal
X43-06928
Clamp and Bushing
Amphenol 97-3057-1007-1
2.0 INSTALLATION
2.1 AC POWER CORD HOOKUP (MO-03074)
Position the strain relief bushing on the line cord as
shown. Insert the line cord into the rectangular hole in
the bottom of the enclosure. Refer to Figure 4.
Make the following connections to terminal block 1TB.
Brown wire
to
L1
Blue wire
to
L2
Green wire
to
G
Using pliers, squeeze the mating halves of the strain
relief bushing together and insert into the enclosure hole.
2.2 TENSION LIMIT DETECTION
RELAY OPTION
If the output contacts are to be used (See Section 3.4),
a conduit hole must be drilled in the enclosure bottom in
order to bring the output contacts external to the tension
indicator.
Use ½ inch electrical trade size conduit. Refer to the
National Electric Code for guidelines governing
installation and wiring.