background image

18 of 18

A800-7425 J

INSTRUCTION 

m

m

.  A800-7425 J (Page 1 of 16)

LIMITATION OF REMEDY AND
LIABILITY.

THE REMEDY PROVIDED HEREIN IS
BUYER'S SOLE AND EXCLUSIVE
REMEDY. 

THE BUYER'S REMEDY

AND  THE COMPANY'S LIABILITY
(WHETHER UNDER THE THEORIES
OF 

BREACH OF WARRANTY,

CONTRACT, TORT INCLUDING
NEGLIGENCE OR STRICT LIABILITY
OR ANY OTHER LEGAL THEORY)
SHALL BE LIMITED EXCLUSIVELY
AT  THE COMPANY'S OPTION TO
REPLACING OR REPAIRING
WITHOUT CHARGE AT THE
COMPANY'S 

FACTORY OR

ELSEWHERE  ANY MATERIAL OR
WORKMANSHIP DEFECTS WHICH
BECOME APPARENT WITHIN ONE
YEAR FROM THE DATE ON WHICH
THE GOODS WERE SHIPPED

. THE

COMPANY SHALL NOT BE LIABLE
FOR SPECIAL, INCIDENTAL OR
CONSEQUENTIAL DAMAGES OF ANY
KIND INCLUDING BUT NOT LIMITED
TO  DAMAGES FOR LOSS OF USE,
INCOME OR PROFIT, OR LOSSES
SUSTAINED AS A RESULT OF INJURY
(INCLUDING DEATH) TO ANY
PERSON OR DAMAGES TO
PROPERTY.  THE COMPANY SHALL
HAVE NO LIABILITY FOR DAMAGES
OF ANY KIND ARISING FROM THE
INSTALLATION AND/OR USE OF THE
GOODS BY ANYONE. BY THE
ACCEPTANCE  OF THE GOODS, THE
BUYER SHALL ASSUME ALL
LIABILITY  FOR ANY DAMAGES
WHICH MAY RESULT FROM USE OR
MISUSE 

BY THE BUYER, ITS

EMPLOYEES OR BY OTHERS.

Summary of Contents for Cleveland-Kidder TMI

Page 1: ...VAC resistive each limit Optional Isolation 0 10 VDC 5 mA or 4 to Amplifier 20 mADC 1500 VRMS Optional 2000V peak isolated Ambient Temperature 0 40EC 32 104EF Relative Humidity 5 to 95 w o condensatio...

Page 2: ...2 of 18 A800 7425 J Figure 1 1 0 GENERAL INFORMATION...

Page 3: ...provides an isolated 0 10 VDC or a 40 20mADC output 1 3 4 Digital AnalogMeter Blank Plate Option A 3 inch digit panel meter or a 5 inch analog meter are available The blank meter plate can be install...

Page 4: ...stment for the digital between 22TB on the isolation amplifier and 3TB tension meter display on the indicator main circuit board It supplies power to operate the isolation amplifier 10 Isolation Ampli...

Page 5: ...the signals in the indicator The Tensi Master indicators can also be used for cantilever wire and single transducer applications 1 0 GENERAL INFORMATION 2 0 INSTALLATION AC VOLTS JUMPER 100 2TB 23 TO...

Page 6: ...n Insert the line cord into the rectangular hole in the bottom of the enclosure Refer to Figure 4 Make the following connections to terminal block 1TB Brown wire to L1 Blue wire to L2 Green wire to G...

Page 7: ...k through this conduit See Figure 5 3 0 ADJUSTMENTS Check that the indicator has been wired correctly per the installation wiring diagram and that the jumper at 2TB is set for the proper line voltage...

Page 8: ...will cause inaccurate calibration B Apply a known tension load using weights or a spring scale If possible the applied load should be approximately the same as the anticipated operating tension If fo...

Page 9: ...rises above the tension limit detector level set point a set of normally open and normally closed relay contacts on the TLD card will switch states 3 5 ISOLATION AMPLIFIER OPTION Mount the isolation a...

Page 10: ...the maximum working force of the transducers in most cases 4 2 LOW OUTPUT SIGNAL The transducer may have too large a maximum working force for the application Replace with a lower maximum working forc...

Page 11: ...ransducer instruction manual 5 0 REPLACEMENT PARTS Description Use P N Lamp Power ON OFF X01 21443 Switch PB Power ON OFF X16 11705 Lens Red Power ON OFF X01 21442 Lamp 28V TLD X01 11702 Switch PB TLD...

Page 12: ...12 of 18 A800 7425 J 7 0 OUTLINE DIMENSIONS...

Page 13: ...13 of 18 A800 7425 J 7 0 OUTLINE DIMENSIONS...

Page 14: ...ALS 1 2 NORMALLY CLOSED AND 3 4 NORMALLY OPEN WHEN TENSION IS WITHIN THE NORMAL OPERATING LIMITS EACH CONTACT IS RATED AT 5 AMP 115 VAC RESISTIVE 1 2 3 4 5 6 7 8 9 10 11 T L D CARD T L D A B 2 4 3 1 O...

Page 15: ...15 of 18 A800 7425 J INSTRUCTION m m A800 7425 J Page 1 of 16 8 0 INSTALLATION WIRING DIAGRAM...

Page 16: ...16 of 18 A800 7425 J 8 0 INSTALLATION WIRING DIAGRAM...

Page 17: ...COMPANY WITHIN THE APPLICABLE WARRANTY PERIOD OR B DUE TO MISAPPLICATION M O D I F I C A T I O N DISASSEMBLY ABUSE M I S U S E I M P R O P E R I N S T A L L A T I O N UNAUTHORIZED REPAIR IMPROPER MAI...

Page 18: ...HERE ANY MATERIAL OR WORKMANSHIP DEFECTS WHICH BECOME APPARENT WITHIN ONE YEAR FROM THE DATE ON WHICH THE GOODS WERE SHIPPED THE COMPANY SHALL NOT BE LIABLE FOR SPECIAL INCIDENTAL OR CONSEQUENTIAL DAM...

Reviews: