Self-diagnostics
Starting the self-diagnostics:
Press button 2 until the illuminated ring underneath the button lights
up orange.
Release the button.
During the self-diagnostics the following will be executed automatically:
1.
The valves will be adjusted.
2.
Red lights up: valve goes into the hot position.
3.
Green lights up: valves closed.
4.
Blue lights up: valve goes into the cold position.
5.
Valves closed.
After the test the light will flash orange:
a.
2x: unit is OK, or
b.
3x: temperature sensor malfunction, or
c.
4x: flow sensor malfunction
8.3 Optional functions
The Easyfill has 2 optional functions which must be enabled before they
can be used. The optional functions are option 1: thermal disinfection and
option 2: reset to factory settings.
Enabling the optional functions
Press button 2 and hold it for +/- 20 seconds. The illuminated ring
lights up turquoise.
Release the button.
After releasing the button the light will flash turquoise
a.
1x flash: options enabled, or
b.
2x flash: options disabled
(Press button 2 again til it will flash turquoise again, then release it, now
you can enable/disable optional functions.)
Option 1: thermal disinfection
Press button 2 until the illuminated ring lights up red.
Release the button
After releasing the button the light will start flashing red for 5
minutes during which time thermal disinfection is executed.
Warning: Hot water, danger of scalding!
Interrupting thermal disinfection:
Press button 2 to interrupt.
After thermal disinfection the system will flush with cold water.