Electrical connection:
junction box.
Connect the installation to a single main circuit breaker, so the whole
installation can be switched off for maintenance with only one switch.
1. Earthing connection
2. Other electrical components (eg. LED light)
3. Power supply 100-240VAC 50-60Hz.
4. Easyfill
Wiring diagram
The wiring diagram can be found under the cover
of the electronics box of the Easyfill.
Electrical connections to the Easyfill
5. equipotential connection (4mm²)
6. Junction box
Testing
Test the Easyfill before fitting the bathtub. Make
sure the system functions properly.
3.3 Water inlet / Water drain
Connections for water inlet and drain shall be installed
according to the currently valid DIN 1988/EN1717 /
DIN1986/EN12056 as well as local regulations.
Pay attention to the position of the tub feet and installation
area when installing the water and waste supplies! The waste
pipe must be positioned at floor level. If the bathtub is fitted
with a whirlpool frame, the waste pipe shall be installed in the floor.
According to DIN EN 12764, a suitable safety device
preventing backflow shall be installed by the customer.
According to EN 1717 this must at least consist of a n HD
safety combination or according to DIN 1988 of a n A1 pipe
interrupter at the respective correct installation height.
6