14
10 Steam pipe
1
The steam pipe must always be made of an isolated copper pipe with a specified minimum diameter. This is 22
mm for generators up to 6 kW. At 9 kW a pipe diameter of 28 mm is used. The steam line is connected to the
generator by means of the supplied rubber, steam hose and the supplied brass bend. It is forbidden to use knees
in the steam pipe. All bends must be carried out with a minimum radius of 50 mm. A knee is only used for the
direct steam inlet in the cabin.
The steam pipe must always be placed at least 600 mm upwards to prevent the flow of hot water drops. The
maximum length of a steam pipe is 3 meters. Make sure the steam pipe runs down to two sides: the steam outlet
and the steam generator. In this way no so-called ‘saggers’ are created, so that gurgling noises can not arise from
stagnant water.
When the installation is provided with a fragrance dispenser, make sure that this pipe does not have any ‘sagger’
in which fragrance remains. For the quality and longtivity of the fragrance it is important that it can flow
directly downwards to the inlet piece. A small ‘curved siphon’ (see drawing) in the inlet piece guarantees the
correct operation.
> 600 mm
> 50 mm
Euca / Fragrance connection
piece preferably near the
steam inlet and accessible