CLEOPATRA Cleo Steam Brain Installation Manual Download Page 1

EN

Cleo Steam Brain

Installation manual

Item no: 

90179999

EN2018/09 R01

Summary of Contents for Cleo Steam Brain

Page 1: ...EN Cleo Steam Brain Installation manual Item no 90179999 EN2018 09 R01...

Page 2: ...ght All information in this technical document together with the drawings and technical specifications made available by Cleopatra B V remain the property of Cleopatra B V and may not be copied withou...

Page 3: ...Overview operation 15 13 Overview of steam inlet 16 14 Placing components in the cabin 16 14 1 Explanation recess holes 17 14 2 Explanation laying cables 18 15 Finishing 19 15 1 Placing sensors 20 15...

Page 4: ...not be accepted by Cleopatra Every right to warranty expires if adjustments have been made to the original product or parts This manual must be kept close to the product for quick access if needed Use...

Page 5: ...are intoxicated Bringing electrical devices in the cabin is forbidden Warning hot surfaces The steam inlet the surrounding area and the steam itself are very hot Do not touch them because of danger of...

Page 6: ...6 3 Required tools and materials 3 Screwdriver cross 2 Drill set 6 Kit gun 1 Drill 4 Spirit level 8 Pencil 5 Square 7 Tapeline 9 Multitool 2 3 1 4 6 7 5 8 9...

Page 7: ...ontrol box H Fragrance pump J Cable tray K Cable clamp L Drain DO NOT DEFORM Only applicable with the optional fragrance dispenser A G C F I J H K O N M M Steam generator N Fragrance reservoir O Fragr...

Page 8: ...sions Power kW A mm B mm C mm D mm Weight kg 3 532 710 190 90 17 kg 4 5 532 710 190 90 17 kg 6 532 710 190 90 17 kg 9 532 710 190 90 17 kg A B C D Only applicable with the optional fragrance dispenser...

Page 9: ...9 6 Installation in the technical area 1 Use the minimum distances as shown in the drawing 7 Mounting on the wall 1 2 3 4 200 mm 200 mm 100 mm X X Space for water drainage and siphon...

Page 10: ...10 5 6 7 8 9 m8 8mm...

Page 11: ...temperature 5 C Maximum humidity 80 not condensing Main voltage 8 10 P Maximum pressure steam cylinder exit 100 mm water Water quality The Cleo Steam Brain generators can use both hard and soft water...

Page 12: ...with adequate ventilation During installation a multi pole main switch must be installed with a contact distance of at least 3 mm The steam bath generator belongs to Protection class I electrical divi...

Page 13: ...below Power Connection Electricity 3 kW 230VAC 1N 50 60Hz 13A 4 5 kW 400VAC 1N 50 60Hz 13A 6 kW 400VAC 1N 50 60Hz 13A 9 1 Next steps electrical connections 9 kW 400VAC 1N 50 60Hz 13A 3 kW 4 5 6 9 kW J...

Page 14: ...00 mm upwards to prevent the flow of hot water drops The maximum length of a steam pipe is 3 meters Make sure the steam pipe runs down to two sides the steam outlet and the steam generator In this way...

Page 15: ...art sensor C Safety sensor A Tube input for the purpose of putting in flexible tube A B C D D Temperature sensor 12 Overview operation A iBox for Steam Brain B Steam Brain control C Rotary knob Steam...

Page 16: ...nee piece D Coupling tube E Wall plate F Steam outlet G O ring H Ring m6 J Steam hood I Bolt m6x50 To make clear how the components can be placed in a cabin we give an example The cabin in the example...

Page 17: ...n parts for the safety sensor and the temperature sensor Min depth 40mm 35mm Min 100mm 3 Drill a recess for the pipe for the steam inlet Min 150 mm Max 180 mm from the floor surface Min 70 mm 14 1 Exp...

Page 18: ...lanation laying cables 4 Place the piping of the steam inlet through the milled hole Guide the cable through the hole in the template 3 Pull the extension cable through the cable tube to the steam gen...

Page 19: ...o ring to the wall plate Provide the back of the steam outlet with kit 5 Place the piping of the steam inlet through the recess When finishing the walls part of the steam outlet must be placed after...

Page 20: ...e distances to the center lines of the hole 61 mm 100 mm 194 mm All distances serve as an example 2 3 Measure and mark these distances on the tile Cut off 2x a hole in the tile with drill 25 and place...

Page 21: ...or and the cabin Connect the cable end of a sensor to the tension spring and use the tension spring to gently pull the cable into the tube If the cable with sensor still sticks about 30 cm outside of...

Page 22: ...cle of 64mm out of the tiles and place the tiles on the wall 2 3 320 mm 137 mm 1 Measure the distances to the center lines of the hole 15 2 Placing steam outlet 320 mm 137 mm All distances serve as an...

Page 23: ...t off the shape from the tiles and place the tiles on the wall 2 3 1 Measure the distances to the center lines of the hole 42 mm All distances serve as an example 530 mm 220 mm 56 mm 42 mm 530 mm 220...

Page 24: ...24 5 Connect the 2 cables together 6 Kit the back of the controls and place it in the wall...

Page 25: ...25 16 Removing the control 1 Gently pull the control with a flat screwdriver 2 Pull out the control 3 Disconnect the cables...

Page 26: ...ntrol temperature and safety sensor cables through the cable glands Cleopatra multimedia module Control Temperature sensor Safety sensor LED Spots module 4 pieces LED Spots module 4 pieces LED rails m...

Page 27: ...27 2 Control RS485 Temperature sensor Safety sensor 3 Temperature sensor Green GN Brown BR White WT Yellow RX Green TX White GND Brown 12V Steam Brain control 4...

Page 28: ...RS485 1 White light 1 Connect plus and minus according to LED specifications If you have only ordered the white light option you can connect the lighting to this module In this case you do not need t...

Page 29: ...29 2 White light 2 Connect plus and minus according to LED specifications 7 8...

Page 30: ...17 2 Connecting Multimedia Module 1 Supply Speaker 1 Speaker 2 RS485 IN RS485 UIT 2 Brown L Blue N Connection supply 3 Green A White B Brown GND Connection RS485 IN Overview connections Multimedia Mod...

Page 31: ...31 5 1 Black Grey 2 Black Red 1 2 4 Green A White B Brown GND Bushing RS485 OUT on other modules Connection speaker 1 and or 2...

Page 32: ...ots module LED spot 1 LED spot 2 LED spot 3 LED spot 4 Supply External push button RS485 IN RS485 OUT 2 Brown L Blue N 3 Green A White B Brown GND 1 Connection supply Connection RS485 IN Overview conn...

Page 33: ...33 4 Green A White B Brown GND 5 1 Red 2 Green 3 Blue 4 Black Bushing RS485 OUT on other modules Connection LED spot 1 2 3 and or 4...

Page 34: ...rails module LED rails 1 max 5m LED rails 2 max 5m Supply External push button RS485 IN RS485 OUT 2 Brown L Blue N 3 Green A White B Brown GND 1 Connection supply Connection RS485 IN Overview connect...

Page 35: ...35 4 Green A White B Brown GND 5 1 Red 2 Green 3 Blue 4 Black Bushing RS485 OUT on other modules Connection LED rails 1 and or 2...

Page 36: ...nsor client Temperature sensor client C4 C5 C1 C2 C3 L1 Mains Blauw Brown 16 16 16 N Mains Grey Black 16 16 L3 Mains Earth Mains L2 Mains Earth Heating element 3 Blue Brown Gr Ye 1 1 N Heating element...

Page 37: ...12 VDC LED client 12 VDC LED client 12 VDC LED client 12 VDC LED cleint Yellow Green White Brown Green White Brown 20 Speaker 1 2 x 0 25 21 Speaker 2 2 x 0 25 23 Comm RS485 2 x 0 25 22 Supply 2x 0 25...

Page 38: ...t 34 34 LED Spot 3 client Green Red S6 LED Spot 4 client 35 35 LED Spot 4 client Black Blue LED Spot 4 client 35 35 LED Spot 4 client Green Red R1 N 230VAC Supply 40 40 L 230 VAC Supply Brown Blue R2...

Page 39: ...9 kW Characteristics 3 kW 230 V 1N AC 50Hz max 3 3 kW Max 14 3A IPx4 inside IP20 outside Class 1 Max 1 0 MPa 10 bar Max 80 C 4 5 kW 400 V 3N AC 50Hz max 4 5 kW Max 11 5A IPx4 inside IP20 outside Class...

Page 40: ...right and to adjust technical changes and printing related color deviations 01 2019 Cleopatra B V Oostzijde 295 1508 EN Zaandam T 31 75 6478200 info cleopatra nl www cleopatra wellness com Identificat...