13
2. LED color ring is illuminating GREEN:
Check if NO water fl ows.
3. LED color ring is illuminating BLUE:
Check if cold water fl ows.
Water fl ows:
− Device is broken, contact Support Center.
No cold water is fl owing:
− Check cold water supply line
− Is cold water stop valve opened?
− Is mesh fi lter ok?
− Are cold and warm water supply lines
correctly connected?
Diagnostic completed:
Flashing 2 × ORANGE:
Diagnostic successfully completed.
Flashing 3 × ORANGE:
Malfunction of the temperature sensors.
Contact Support Center.
Flashing 4 × ORANGE:
Malfunction of the fl ow rate sensors.
Contact Support Center.
Troubleshooting if LED color ring is NOT
illuminating:
Please check the cable connection between
TLC Controller and Interface. If you were
unable to resolve the issue, please contact
Support Center.
Special functions
Changing between activation / locking device
press & hold
knob 1 until LED color ring is
fl ashing TURQUOISE. Release knob immedia-
tely.
Press & hold
knob 1 until LED color ring is
fl ashing TURQUOISE. Release knob
immediately.
Flashing 1 × TURQUOISE:
Special functions activated
Flashing 2 × TURQUOISE:
Special functions locked
Press & hold
knob 1 until LED color ring is
fl ashing TURQUOISE. Release knob
immediately.
Flashing RED: Flushing with hot water
Stop disinfection
Run disinfection
Press 1 ×
knob 1 or wait 5 minutes
(automatic stop)
Thermal disinfection *
ATTENTION: RISK OF SCALDING!
Press & hold
knob 1 until LED color ring is
fl ashing BLUE. Release knob immediately.
Flashing 2 × BLUE: Factory setting restored.
Functions are depending on the TwinLevel controller used.
Factory setting *
* Special function must be activated