12
Scalding protection
Turning
knob 1: Changing temperature.
From
≥
38° C temperature increase in smaller
increments (more wheel turns).
Reset Quick Access
(Special function must be activated)
Press 1 ×
knob 1,
water ON like Quick Access 1
Press & hold
knob 1 until LED color ring is fl ashing DARK BLUE. Release knob immediately.
Flashing 2 × DARK BLUE: Water OFF, reset settings. (fi lling quantity is deactivated, temperature
and water fl ow like factory setting)
Press 2 ×
knob 1
briefl y,
water ON like Quick Access 2
Press 3 ×
knob 1
briefl y,
water ON like Quick Access 3
Diverting
(tub / head-/ hand shower)
Press & hold
knob 1 until LED color ring is
fl ashing LIGHT BLUE. Release knob
immediately. Pop up open or close.
Pop up open / close
Press 1 ×
knob 1: Water ON
Press
knob 2
briefl y:
Diverting tub
<>
hand and head shower
Quick Access 1
Quick Access 2
Quick Access 3
Activating the cleaning mode
Press & hold
knob 1 until LED color ring is
fl ashing GREEN. Release knob immediately.
Press & hold
knob 1 until LED color ring
GREEN goes out or wait 45 seconds.
(automatic reactivation)
Deactivate Interface
Reactivate Interface
Diagnose
1. LED color ring is illuminating RED:
Check if hot water fl ows.
Press & hold
knob 1 until LED color ring is
fl ashing ORANGE. Release knob immediately.
Start Diagnostic:
No warm water is fl owing:
− Check the hot water supply line
− Is hot water supply line open?
− Is hot water system activated?
− Is mesh fi lter ok?
− Are cold and warm water supply lines
correctly connected?