3. System Overview 

3.1 Overview of PV-ezRack SolarRoof Isolator Shade 

 

 

 

 
 
 

 
 
 
 
3.2 Precautions during Stainless Steel Fastener Installation 

Improper operation may lead to deadlock of Nuts and Bolts. The steps below 

should be applied to every stainless steel nut and bolt assembly to reduce this 

risk.   

 

3.2.1 Reduce the friction coefficient: 

1

Ensure that the thread surface is clean (no dirt or contaminant) 

2

Apply lubricant (grease or 40# engine oil) to fasteners prior to tightening 

to avoid galling or seizing of threads; 

 

3.2.2 General installation instructions: 

1

Apply force to fasteners in the direction of thread 

2

Apply force uniformly, to maintain the required torque   

3

Professional tools and tool belts are recommended 

4

Avoid using electric tools for final tightening 

5

Avoid working at high temperatures 

 

3.2.3 Safe Torques 

Please refer to safe torques defined in this guide.   

 
 

 

Isolator Cover 

Isolator Bracket 

Isolator 

Reviews: