Installation Guide / SolarRoof Terracotta Tile
32
Code-Compliant Planning and Installation Guide V 1.0 - Complying with AS/NZS1170.2-2011 AMDT 2-2016
- Certification -
October 2020 | Page 14
PV-ezRack SolarRoof Interface spacing tables
Type of Rail
ER-R-ECO (Refer to
Note 7
for other compatible rails)
Type of Interface
ER-I-05 (Tin Interface)
Solar Panel Dimension
2 m x 1 m (Refer to
Note 13
for other panel sizes)
Terrain Category
3
Roof Angle - 0° <
α
< 10°
Wind
Region
Building Height (m)
H < 5
5 < H < 10
10 < H < 15
15 < H < 20
20 < H < 30
U.W &
D.W
Central
U.W &
D.W
Central
U.W &
D.W
Central
U.W &
D.W
Central
U.W &
D.W
Central
A
1744
1919
1735
1909
1671
1838
1597
1757
1450
1595
B
1528
1681
1524
1676
1423
1565
1285
1414
1148
1262
C
1102
1212
1092
1202
946
1040
845
929
753
828
D
689
757
679
747
606
666
532
586
468
515
Roof Angle - 10° <
α
< 20°
Wind
Region
Building Height (m)
H < 5
5 < H < 10
10 < H < 15
15 < H < 20
20 < H < 30
U.W &
D.W
Central
U.W &
D.W
Central
U.W &
D.W
Central
U.W &
D.W
Central
U.W &
D.W
Central
A
1735
1909
1726
1898
1666
1833
1588
1747
1446
1590
B
1524
1676
1519
1671
1418
1560
1276
1404
1138
1252
C
1102
1212
1088
1197
936
1030
840
924
748
823
D
684
752
670
737
601
661
523
576
464
510
Roof Angle - 20° <
α
< 30°
Wind
Region
Building Height (m)
H < 5
5 < H < 10
10 < H < 15
15 < H < 20
20 < H < 30
U.W &
D.W
Central
U.W &
D.W
Central
U.W &
D.W
Central
U.W &
D.W
Central
U.W &
D.W
Central
A
1680
1848
1662
1828
1597
1757
1524
1676
1377
1515
B
1515
1666
1423
1565
1368
1505
1248
1373
1102
1212
C
1203
1323
1065
1171
918
1010
826
909
725
798
D
776
853
652
717
588
646
514
565
450
495