stream within the mixing chamber, and is propelled out
the nozzle. After striking the object being blasted, the
blast media, fines, dust, and by-products generated by
blasting, fall through the mesh grate and into the cabinet
hopper. These particles are conveyed from the cabinet
hopper by way of the flex hose and into the reclaimer for
separation. Dust and fines are first separated from
reusable media and pulled into the dust collector. Next,
the media is screened for oversize particles, and
returned to the reclaimer hopper for reuse.
1.5.2 Dust Collector
1.5.2.1
The final stage of the recovery, reclaiming
process takes place in the dust collector. Dust and fines
drawn through the reclaimer are trapped on the outer
surface of the filter cartridges, discharging clean air
through the exhauster.
1.5.2.2
At regular, timed intervals, the dust-collector
filter cartridges are cleaned by a pulse of high velocity
compressed air expanding against the inner surface of
the cartridges. The expanding air momentarily reverses
air flow through the cartridges releasing trapped dust.
The dust particles fall away from the cartridges into the
hopper for removal.
1.5.2.3
The pulse interval is controlled by a timer
located inside the sequence panel. The timer controls
the ON time (the length of time for each pulse) and OFF
time (the length of time between each pulse). The ON
time should never be adjusted. The lower the setting for
the OFF time, the shorter the length of time between
pulses.
Figure 3
POWER MODULE
Exhauster
Control Panel
Dust Collector
Dust Container
Pulse Reservoir, 1 of 2
Reclaimer
● Pulse Pressure Regulator
Air supply inlet from cabinet plumbing,
refer to Figure 2.
Outlet Damper
Filter Cartridges (2)
Access Door
Pulse-Sequence Panel
Metering Valve ▼
Media hose connection,
refer to Figure 2.
Reclaimer Inlet
Diaphragm Pulse Valve
Forklift Slots
Reclaimer Access Door
Optional Differential-Pressure Gauge
Adjustable Vortex
Pulse Reservoir Drain Cock
Debris Screen
Lower Cone and Stand Asembly