The following parameters can be programmed in the particular FastApp configuration. See 3.6.1 Configur-
ing FastApps, page 18 and 3.6.4 Advanced settings, page 20.
Parameters
Explanation
Range of values
Abbrev.
Speed (rpm)
Speed selection: In the range of the
maximum speed specified in the tool
constants, with validity at the begin-
ning of the sequence up to the
threshold torque.
Begin: With tool start
End:
•
Threshold Torque
•
Speed threshold
± Maximum speed
n
Speed Threshold (rpm)
a
a. The maximum torque is not normally reached. The torque shutoff value is less than the maximum torque.
Therefore, it is not completely regulated to the final speed.
Speed when the maximum torque is
reached. Must be less than the start-
ing speed (rpm).
FastApps mode
As soon as the speed threshold is
reached, the speed is reduced from
the starting speed to the final speed
at the maximum torque. With
increasing torque, the speed drops.
Begin: From the Speed
Threshold
Torque
End:
Shut-Off Torque
mPro mode
In mPro mode, the parameterization
of the controller is valid.
± Maximum speed
n2
Maximum Angle (deg)
Upper limit of attained angle.
0 … 9 999
AngMax
Maximum Torque (Nm)
Upper limit of attained torque.
0 … 1.2 x TQ capacity
TqMax
Minimum Angle (deg)
Lower limit of attained angle.
0 … 9 999
AngMin
Minimum Torque (Nm)
Lower limit of attained torque.
0 … TQ Shut-Off Torque
TqMin
Threshold Torque (Nm)
Beginning of angle counting.
0 … TQ capacity
TqTh
Shut-Off Torque (Nm)
Valid monitoring torque during the
tightening process. If the monitoring
torque is exceeded, the drive stops
immediately.
0 … TQ capacity
TqP
Shut-Off Angle (deg)
0 ... 9999
AP