background image

1

 

EN

 

  

 

 

 

 

 

P2547BA | 2021-07 

Apex Tool Group 

EN 

Power Tool Use and Care 

  Only use bits or sockets designed for industrial use 

with machine-controlled tools. 

  Make sure that the bit or socket is securely inserted. 

  Do not attach the bit or socket to the screw head at an 

angle. 

  Inspect the bit or socket for visible damage and 

cracks. Replace damaged screw bits immediately. 

  

  Do not open the battery. 

  

3  Items Supplied 

Inspect the product for shipment damage and ensure that 

all items have been received: 

  

  Correct tool (without battery) 

  

  Torque wrench Order no. 204963 (#1 Phillips) 

  

  Instruction manual 

  EU Declaration of conformity 

  Warranty 

  

4  Transport / Storage 

  Transport or store in the original packaging. The 

packaging is recyclable.  

  If the packaging is damaged, check the product for 

visible damage. Inform the transporter, if necessary, 

your Sales & Service Center. 

  

  Disconnect the power supply during storage. Refer to 

see chapter 9 Ambient conditions, page 11

 

  

5  Product Description 

Battery powered hand held nutrunner used for the tighten-

ing / loosening of threaded fasteners: 

  

  Work Light for secondary OK/NOK visual feedback. 

  Connects easily over WLAN and Bluetooth 4.0. 

  

 

Abb. 1-1: Product description CLBP(...) and CLBA(...) 

Status light 

Output 

Reverse Switch 

Start Trigger 

Work light 

Battery (sold separately) 

Micro USB-B Port 

 

  

5.1  Status Indication 

The color and duration of the LED display indicate the sta-

tus of the rundown and the tool. 

  

Status light  Work light 

Sound  Meaning 

 

 15 s 

 

 3 s 

 

▬ 

  Result after fas-

tening cycle OK 

 

 15 s 

 

 3 s 

 

Result after fas-

tening cycle 

NOK 

 

 1 s 

 

1 s 

 

Restart Delay 

 

 1 s 

 

1 s 

 

Double Hit Pro-

tection 

 

▬ 

 

 3 s 

After releas-

ing the start 

trigger 

 

▬ 

  Work light is ac-

tivated by start 

trigger  

 

▬ 

 

15 s 

 

3 s 

 

▬ 

  Batch OK (over-

all tightening re-

sult) 

 

▬ 

 

15 s 

 

3 s 

 

▬ 

  Batch NOK 

(overall tighten-

ing result) 

Summary of Contents for CellClutch CLBA Series

Page 1: ...For additional product information visit out website www clecoTools com Instruction Manual P2547BA INT 2021 07 CLBA CLBP Cordless EC Tool...

Page 2: ...rves the right to modify supplement or improve this document or the product with out prior notice Trademark Cleco Production Tools is a registered trademark of Apex Brands Inc Manufacturer Apex Tool G...

Page 3: ...8 1 Right Angle 10 8 2 Pistol 11 9 Ambient conditions 11 10 Troubleshooting 11 10 1 Tool 11 11 Disposal 13 DE 1 Zu diesem Dokument 14 2 Sicherheit 14 2 1 Warnungen und Hinweise 14 2 2 Symbole auf dem...

Page 4: ...4 P2547BA 2021 07 Apex Tool Group INT 10 1 Werkzeug 21 11 Entsorgung 22...

Page 5: ...r serious inju ries Keep this document in a safe place for future refer ence These safety instructions must be accessible at all times to all persons who use the product 2 1 Warnings and Notices Warni...

Page 6: ...loyees have the training and experience to identify potentially hazardous situations They can initiate Position Director R D Address 670 Industrial Drive Lexington SC 29072 United States Phone 1 803 9...

Page 7: ...rce and or remove the battery pack if detachable from the power tool before making any adjustments changing accessories or storing power tools 2 NOTE The term residual current device RCD can be replac...

Page 8: ...rm the transporter if necessary your Sales Service Center Disconnect the power supply during storage Refer to see chapter 9 Ambient conditions page 11 5 Product Description Battery powered hand held n...

Page 9: ...0543 Argentina T50 1000544 United Kingdom T50 1000545 China T50 1000546 Japan Order no Country T50 1000500 North America 6 Bay T50 1000508 Europe T50 1000547 United Kingdom Setting the torque Caution...

Page 10: ...rque Range Speed r min Weight A B C Output Order no Nm ft lb Min Nm ft lb Max Min Max kg lb mm in mm in mm in CLBA083 CLBAW083 x 2 2 1 6 8 0 5 9 92 915 1 46 3 2 452 5 17 81 76 0 2 99 12 5 0 49 3 8 CLB...

Page 11: ...12 1 4 CLBP12Q CLBPW12Q 3 2 2 4 12 0 8 8 70 700 1 05 2 3 213 5 8 41 209 0 8 23 28 5 1 12 1 4 Values without battery 9 Ambient conditions Features Data Operation site Indoors Working temperature 0 C 40...

Page 12: ...t the torque shutoff value and or angle setpoint are correct Adjust as necessary Check whether the fastening joint has changed significantly Tool does not change speed Speed is the same in all stages...

Page 13: ...t be specially disposed of Separate the components of the packing and segregate the different materials before disposing of them Follow the locally applicable regulations Observe generally valid dispo...

Page 14: ...weisungen lesen Die Nichtbeachtung der Sicherheitshinweise und Anwei sungen k nnen einen elektrischen Schlag Brand und oder schwere Verletzungen verursachen Dieses Dokument f r zuk nftige Verwendungen...

Page 15: ...erkennen Sie k nnen entsprechende Sicherheitsma nahmen Das Werkzeug NICHT als Hammer verwenden NUR Steuerungen einsetzen die in der EU Konformit tserkl rung aufgef hrt sind Das Werkzeug NICHT in explo...

Page 16: ...Alkohol oder Medikamenten stehen Ein Moment der Unachtsamkeit beim Ge brauch des Elektrowerkzeuges kann zu ernsthaften Verletzungen f hren b Tragen Sie pers nliche Schutzausr stung und im mer eine Sc...

Page 17: ...ei denen die Schraube verborgene Stromleitungen oder das eigene Netzka bel treffen kann Der Kontakt der Schraube mit einer spannungsf hrenden Leitung kann auch metallene Ger teteile unter Spannung set...

Page 18: ...Statuslicht Arbeitslicht Ton Bedeutung 15 s 3 s Takten NIO gesamtes Schrau bergebnis Bis Ende Ereignis Bis Ende Ereignis Werkzeug ist berhitzt Bis Ende Ereignis Wartungssignal Bis Ende Ereignis Bis E...

Page 19: ...orisiertem Personal erlaubt Das ffnen des Werkzeugs bedeutet den Verlust der Gew hrleistung Im Reparaturfall das komplette Werk zeug an Sales Service Center senden Hinweis Falsche Kalibrierdaten Nach...

Page 20: ...73 491 5 76 15 0 3 8 CLBA403 CLBAW403 x 15 1 41 19 190 1 83 513 0 76 18 5 3 8 Werte ohne Akku 8 2 Pistole Werkzeug WLAN Drehmoment Nm Drehzahl r min Gewicht A B C Abtrieb Bestell Nr Min Max Min Max kg...

Page 21: ...at der Linkslauf des Drehrichtungsumschalters keine Funktion Werkzeug startet nicht bei akti viertem Linkslauf Parameter f r Drehzahl im Linkslauf ist auf 0 1 min einge stellt Drehzahl Linkslauf param...

Page 22: ...Service Center schicken Werkzeugtemperatur ist zu hoch Werkzeug abk hlen lassen Die aktuelle Ver schraubung kann beendet aber keine neue be gonnen werden Akkuspannung ist zu niedrig Akku tauschen War...

Page 23: ......

Page 24: ...ce Chevalier ZI 77330 Ozoir La Ferri re France Phone 33 1 64 43 22 00 Fax 33 1 64 43 17 17 GERMANY Apex Tool Group GmbH Industriestra e 1 73463 Westhausen Germany Phone 49 0 73 63 81 0 Fax 49 0 73 63...

Reviews: