Page 7
TM12-1103-LG1
08/25/2017
EN
General Safety Instructions Controller
→ Do not modify the nutrunner control, any guard or
accessory unless approved in writing by Apex Tool
Group LLC.
→ Do not try to open the nutrunner control or the components
of the control. Neither for troubleshooting, nor to perform
other work on the unit. Any interference can cause an
error resulting in serious injury from electrical shock.
Operating with an open controller can cause;
• increased emissions: other equipment may be affected.
• reduced immunity: the nutrunner control may cause
erroneous results.
• Opening the nutrunner control will void existing
warranties.
→ Send the complete nutrunner control for repair to your
Sales & Service Center.
1 Designated use
This product is part of the APEX tightening system and is
intended only for industrial use in fastening processes.
→ Use the nutrunner control only under the following
conditions:
• In conjunction with the APEX tools.
- Corded tools
- Cordless LiveWire EC tools
- Built-in nutrunner
• With the approved APEX accessories and cables.
• With the allowable supply voltage.
• Exclusively at the rate for the nutrunner.
• Using the approved maximum cable length.
• Using indoors only.
• Only in industrial EMC limit value class A
→ Do not use the nutrunner control
• in hazardous areas.
• in damp rooms / outdoors.
2 Ambient conditions
→ Keep the nutrunner control away from heat, fire, risk of
explosion and moisture.
3 Required power supply connection
→ Operate only on grounded network (TN network).
Operation in connection with an IT Network is
inadmissible.
4 Install
Danger of crushing. The nutrunner control may fall down
and crush your feet.
→ Use suitable lifting equipment.
→ Wear safety shoes.
→ Ensure sufficient mounting of the nutrunner control: 4xM6,
secured against loosening (see Hardare Description
P2174HW).
→ Lay all connected cables and line safely, so that they are
not damaged and no one can trip over them.
→ Do not exceed a total cable length of 65.6 ft. (20 m). If
longer an APEX isolating transformer, order number
544185PT, is necessary.
In case of failure, high voltage leakage may occur and cause
injuries as mentioned previously.
→ Use enclosed power cable. When changing use a
standard-compliant network management.
→ At 115 VAC: Use cables with a larger cross section.
→ Establish equipotential bonding between machine/
workpiece and tool.
→ Before energizing the nutrunner control ensure that all
connections have been properly made (see Hardware
Description P2174W).
5 Before initial operation
→ Before initial operation perform PE measure according
to locally applicable regulations (DGUV Vorschrift 3 in
Germany).
→ Observe the safety notes on the nutrunne control and
the tool.
→ Check the nutrunner control, tool, and cable for any
obvious defects.
→ During changeover, cleaning and taking out of service
shut off and disconnect the nutrunner control before
connecting the power and tool cable.
6 Operating
→ Immediately shut off the nutrunner control in the case of
unusual sound, vibration or odor. Disconnect the power
supply and have qualified personnel check the tightening
system and repair as necessary.
→ Replace damaged cables immediately.
Function
Temperature
Relative
Humidity
Working
Height
Transport /
Storage
-13°F to +158°F
(-25°C to +70°C)
Ope32°F to +113°F
(0°C to +45°C)
0…90%
non-condensing
up to 9800 ft.
(3000 m)
above sea level
Nutrunner
Control
Input Voltage,
Single Phase
Frequency
Input
Current
16 A max.
mPro400GC-P
115 VAC (104-126 VAC)
230 VAC (207-254 VAC)
2 A
1 A
mPro400GC-P230
230 VAC (207-254 VAC)
1 A
mPro400GC-S
115 VAC (104-126 VAC)
230 VAC (207-254 VAC)
2 A
1 A
mPro400GC-S230
230 VAC (207-254 VAC)
1 A
mPro400GC-M
115 VAC - 230 VAC
(104-254 VAC)
1 A - 0.5 A
mPro400GC-E
115 VAC (104-126 VAC)
230 VAC (207-254 VAC)
2 A
1 A
mPro400GC-I
115 VAC (104-126 VAC)
230 VAC (207-254 VAC)
2 A
1 A
50-60 Hz
Summary of Contents for 48CAE105AH4
Page 2: ......
Page 77: ...Page 77 TM12 1103 LG1 08 25 2017 ZH OK NOK Apex Tool Group LLC Apex Tool Group LLC 1 CE EAC...
Page 78: ...Page 78 TM12 1103 LG1 08 25 2017 ZH 1 2 1 1 3 A 4 5 6 7 8 ElektroG BattG 320 V 1...
Page 84: ...Page 84 TM12 1103 LG1 08 25 2017 ZH 6 RPM 0 rpm 10 LED x mPro40 0GC Air LB Matrix 1 2...
Page 126: ......
Page 127: ......