46
P1890E/EN 2013-08
2291e-en_TroubleShooting_bedingt.fm, 25.08.2017
Troubleshooting
10
Occasional interrup-
tions in data commu-
nication.
Distance between the
base station and tool
is too great.
Increase the power on the base station and tool or
reduce the distance between the base station and the tool.
Transmission power
is too low.
Increase the power on the base station
and tool.
Excessive data traf-
fic on WLAN Net-
work.
Reduce data traffic on WLAN Network.
On the control screen
Basic
,
increase the
Initial Tor-
que
.
On the control screen
mPro >
Main Menu > System Pro-
gramming > Special Func-
tions > MWF
, disable the
torque graph data transmis-
sion.
On the control screen
mPro >
Main Menu > Application Buil-
der > Settings > Fastening
Stages > Fastening Stage # >
Fastening Sequence
,
increase the
Initial Tor-
que
.
Too many tools on
the same wireless
channel.
Use different channels for different base stations.
Other 2.4 GHz
machines use the
same wireless fre-
quency.
Use a different channel.
Cell planning as per Instruction Manual for the base station
Distance for
wireless transmis-
sion is less than
expected.
Transmission power
is too low.
Increase the power on the base station and tool.
Installation location of
the base station is
unsuitable.
Place the base station in a location where there is a clear line of
sight between the base station and the tool.
1) Software-dependent measure. Discrepancy possible when using Custom Tool Software.
Problem
Possible cause
Measure for mPro400GC
(SW S168813)
Measure for mPro400S…
(example SW 168841)
1)
RF15.4 data communication between controller and tool
Summary of Contents for 17BP
Page 1: ...17BP Cordless EC tool Instruction Manual P1890E EN 2017 06...
Page 20: ...Initial operation 7 20 P1890E EN 2017 06 2291b en_1_3_bedingt fm 25 08 2017...
Page 38: ...38 P1890E EN 2017 06 2291c enu_LCD_bedingt fm 25 08 2017 LCD display 8...
Page 48: ...48 P1890E EN 2013 08 2291e en_TroubleShooting_bedingt fm 25 08 2017 Troubleshooting 10...
Page 55: ...1890g en_TechnDaten fm 25 08 2017 P1890E EN 2017 06 55 Technical specifications 12...