Troubleshooting
10
Problem
Possible cause
Measure for mPro400GC
(SW S816813)
Measure for mPro400S…
(example SW 816841)
1)
WLAN data communication between controller and tool
No WLAN data com-
munication between
the controller and
tool.
The IP address of the
tool is not correctly
entered in the con-
trol.
On the control screen
Tool
Setup
, check whether the IP
address of the tool has been
entered in the field
Type
.
Otherwise, mark the line and
<Edit>.
IP address of tool – see Tool in
submenu
Wireless Settings
.
Press <
> on the control.
Select the required tool under
TM Unit #
>
Tool Assign-
ment
.
Press <
>.
Enter the IP address under
Tool Address
.
IP address of tool – see Tool in
submenu
Wireless Settings
.
Tool not yet parame-
terized with the cor-
rect WLAN settings.
On the control screen
Tool
Setup > RF Settings
, parame-
terize the tool with the infra-
red interface with the correct
WLAN settings.
On the control screen
Main
Menu > System Programming
> Service > TMA Configura-
tion > Communication with
Tool
, select >
RF Mode
WLAN.
Parameterize the tool with the
correct settings via the infra-
red interface.
WLAN settings are
different for control
and access point.
On the control screen
Tool
Setup > RF Settings
, check
whether the WLAN settings
for the tool agree with the set-
tings for the access points
(network name, encryption,
network key).
On the control screen
Main
Menu > System Programming
> Service > TMA Configura-
tion > Communication with
Tool
, check whether the
WLAN settings for the tool
agree with the settings for the
access point (network name,
encryption, network key).
A filter for MAC
addresses is acti-
vated at the Access
Point.
Add the MAC address for the tool to the list of approved addresses
at the Access Point.
MAC adress of tool – see
•
Label above the battery
•
On the tool in the
Wireless Settings
submenu.
Port 4001 is disabled
by a firewall.
Configure the firewall such that the required IP/MAC addresses
can use port 4001.
The wireless chan-
nel at the access
point is outside the
range supported by
the tool.
To change the wireless channel setting at the access point to the
right wireless channel with respect to country code:
EU 1–13; World 1–11 (see Installation Manual P1894E).
Tool is already
assigned to another
control.
Check whether another control already has a connection to this
tool. In other words, another tool is using the same IP address.
IP address cannot be
pinged.
IP Address already
exists in network. In
this case, the tool will
not build up a con-
nection.
Check the physical connection (RSSI values).
Check the assigned IP address.
Summary of Contents for 17BP
Page 1: ...17BP Cordless EC tool Instruction Manual P1890E EN 2017 06...
Page 20: ...Initial operation 7 20 P1890E EN 2017 06 2291b en_1_3_bedingt fm 25 08 2017...
Page 38: ...38 P1890E EN 2017 06 2291c enu_LCD_bedingt fm 25 08 2017 LCD display 8...
Page 48: ...48 P1890E EN 2013 08 2291e en_TroubleShooting_bedingt fm 25 08 2017 Troubleshooting 10...
Page 55: ...1890g en_TechnDaten fm 25 08 2017 P1890E EN 2017 06 55 Technical specifications 12...