
4
F. Electrical
Any electrical connections should be performed by a certified electrician in accordance with all
electrical codes.
OzoneMAX
systems are universal voltage, meaning the unit will work on 115 or
230VAC without any internal switching. When locating the power source, make sure that when the
pump and motor shuts off, the
OzoneMAX
will too. The ideal source is the timer box. If no timer box
exists, the unit can use the pump motor as its power source. In other words, the electrical connection
should be such that the
OzoneMAX
is supplied power only when the power is supplied to the pool
filter/circulation pump.
A permanent ground bonding connector is provided on this unit and should
be used to connect a minimum 12 AWG solid copper wire conductor to any
metal equipment, metal enclosures of electrical equipment, metal water pipe,
or conduit within five (5) feet of the unit.
Power Source/
Pump Timer
Pump
Electrode
POOL
Filter
Heater
Kynar check valve
¼” reinforced vinyl hose
Venturi Injector
Clear view window
2” manifold with
venturi injector and
ball valve assembly
1½” reducer bushings (if needed)
water flow
N = Nylon Hose Clamps
N
N
N
N
G. Installing the Venturi Injector
Mount the venturi manifold on the return line (after the filter, pump, electrode chamber, heater, etc.) so
it is the last item before entering the pool. This is very important.
MAKE SURE THE WATER FLOWS IN THE DIRECTION OF THE ARROWS MARKED ON THE
VENTURI MANIFOLD.
The venturi manifold comes in two-inch pipe. If plumbing size is 1 ½”, you will need to add 2” x 1 ½”
reduced bushings on each end of the manifold (included with the venturi manifold package.)
Continue on next page >>>
N = Nylon Hose Clamps