Vacuum-ultraviolet Ozone Systems
TM
Ozone
MAX
3
Model
OZ-50
Installation
&
Operation Manual
Page 1: ...Vacuum ultraviolet Ozone Systems TM OzoneMAX 3 Model OZ 50 Installation Operation Manual ...
Page 2: ...diately If electrically connecting this unit directly to pool controls ensure the controls are protected by a G F C I Ground Fault Circuit Interrupter Install at least five 5 feet from wall of pool water using nonmetallic plumbing Install ozone generator no less than one 1 foot above the maximum water level to prevent water from contacting electrical equipment Install in accordance with the instal...
Page 3: ...s Hacksaw or Pipe Cutter PVC Cement PVC Cleaner Primer Utility Knife Screwdrivers Flat Phillips Screws Anchors within 6 feet within 8 feet Power Source TimerBox OzoneMAX Unit Venturi Injector E Installing the Power Box Mount the OzoneMAX unit to a post or wall using the four mounting screw holes in the enclosure base The unit may be mounted horizontally or vertically however it is recommended that...
Page 4: ...G solid copper wire conductor to any metal equipment metal enclosures of electrical equipment metal water pipe or conduit within five 5 feet of the unit Power Source Pump Timer Pump Electrode POOL Filter Heater Kynar check valve reinforced vinyl hose Venturi Injector Clear view window 2 manifold with venturi injector and ball valve assembly 1 reducer bushings if needed water flow N Nylon Hose Clam...
Page 5: ...RISK SERIOUS INJURY Cut the hose at the areas depicted to the left to add the Kynar check valves These location should be within 6 of the ozone output coming from the OzoneMAX connector and 6 of the venturi manifold input connector Add the Kynar check valves in line in both locations Connect one end of the hose to the OzoneMAX output connector and the other end to the venturi input connector on th...
Page 6: ... in the evening to ensure the unit is functioned correctly Turn the system on temporarily if needed The indicator light located next to the output connector will glow a nice blue color The ozone unit should only be on when the pump is running To insure that the venturi injector and bypass are working correctly simply observe to see if small bubbles are entering the pool and the frothing effect is ...
Page 7: ...om the wall This is to insure you carefully remove the delicate equipment from the metal enclosure properly and seal back up tightly Replacing the bulb in the OzoneMAX unit 1 Disconnect power from the OzoneMAX unit Coming into contact of the exposed ozone bulb can cause serious damage to your health 2 Remove the six 6 screws on the bottom of the unit Continue on next page J Periodic Inspection con...
Page 8: ...ce inside the unit There is no need to add another zip tie as this was used for shipping purposes 8 Replace the bottom plate making sure the gasket is seated in the groves properly 9 Tighten the 6 screws back into place securing the bottom plate tightly 10 Reconnect power Make sure the bulb indicator the clear connector on the output tube of the power box glows in a blue color Again you may want t...