OZONE GENERATOR TROUBLESHOOTING (continued)
PROBLEM/SYMPTOM
POSSIBLE CAUSE
SOLUTION
Unit seems noisy
Not properly secured to wall/floor
Bolt it firmly into place
Shipping damage
Locate and repair
Fan blocked
Check and clear obstructions
Flow meter will not adjust
Air preparation not operating
Make sure air prep package is
set properly
Defective solenoid
Inspect and repair or replace solenoid
Defective check valve
Check and replace check valve
Vacuum gauge reads on
Insufficient vacuum
Adjust injector vacuum
pressure side
Output solenoid defective
Check and replace or rebuild
Defective vacuum gauge
Replace vacuum gauge
Loose Kynar
®
compression fittings
Tighten all Kynar
®
fittings
to ozone delivery line