3. Locate four (4) QH1070 pipe straps and attach each
strap to the rafter assembly on the underside of the
rafter at each tube joint as shown.
NOTE:
The screws used to secure the pipe straps to the
rafter are also used to secure the joint of the two rafter
tubes. When installing the pipe straps, verify that you are
installing the screws through one pipe and into the
swaged end of the other pipe at the joint.
IMPORTANT:
DO NOT tighten the screws at this time.
These will be tightened after installing the purlins.
4. Once the rafter tubes for the first rafter are
assembled and the QH1070 pipe straps are
attached to the underside of the rafter tubes, select
the required tubing and brackets to assemble and
attach the center bracing. The required parts for one
(1) rafter are listed below:
2 (S20P064): 2" x 2" plain sq. tubes at 64" each
1 (104075): 1.75" x 1.75" plain tube at 16" (insert)
1 (S20P020): 2" x 2" plain sq. tubes at 20" each
1 (104624): Square Tube Fitting w/1-way plate
4 (105087): Connection Plate (angled at top)
1 (105086): Vertical Bracket
ATTENTION:
All parts are secured using the
FA4482 Tek screws.
5. Locate the 20" vertical tube (S20P020) and attach
the vertical bracket (105086) to one end of the
vertical tube.
6. Select the two (2) 64" plain tubes (S20P064) and
connect them using the 16" plain tube insert
(104075) and Tek screws. This is the horizontal (or
lower) portion of the center bracing for the rafter.
7. After connecting the two 64" square tubes, identify
the center of the assembly and mark the location.
2" x 2"
2" x 2"
Tek Screws
Insert
Pipe Strap Locations
105086
S20P020
Visit www.ClearSpan.com for additional products and customer assistance.
7 of 22