17
CLEARSPAN
™
PONY WALL BUILDINGS
Revision date: 11.28.17
108467_68_69_70
Cover Conduits
Cover
Ends w/
Strapping
Stretch
Pockets
Conduit Pocket
Conduit Pocket
Pull this end up
and over frame
Use liquid dish soap to lubricate
the conduit and pocket when
inserting the conduit if needed.
Example of a
"fan-folded" cover
Frame length of your building
may differ from what is shown.
Rope or strap used to secure
free end of cover as other edge
is pulled over the frame. See
Step 2 on the next page.
NOTE:
When handling the main cover and setting it in position, do not pull on the end straps. They will
pull out of the cover.
Do not insert any cover conduit into a cover pocket that includes a pre-installed strap.
WARNING:
To prevent damage to the cover and to prevent serious personal injury,
do not attempt to
install the main cover on windy days
.
1. Assemble two main cover conduits. Start each cover conduit assembly with one plain pipe and add
swaged pipes to arrive at the length of the frame. Secure each joint with a Tek screw and wrap the
screw and joint with duct tape. Once assembled, the cover conduits are inserted into the side pockets
of the main cover. The conduits are used to tighten and secure the main cover to the frame.
Consult
the Side Profile Diagram in the Quick Start section for pipe identification.
2. After assembling the cover conduits, locate the main cover and partially unfold it on a clean, smooth
surface near the frame. Unfold the main cover with the inside surface facing up and the straps
positioned at the front and back of the frame. If the cover is "fan folded" (see insert below), see the
information on the next page.
Unroll, but do not unfold a fan-folded cover at this time.
3. Align the cover ends–ends have pre-installed straps–with the front and back of the shelter and insert
one cover conduit into each side pocket of the main cover. Tape or cover the end of conduit with part
of a plastic soda bottle and insert that end into the pocket for easier installation.
4. Continue by pulling the cover up and onto the frame.
PREPARE MAIN COVER
Gather the parts:
• Pipe 1.90" x 99" swaged
• Pipe 1.90" x XX" plain
• Main cover
• FA4482B Tek screws and duct tape
NOTE:
The "XX" represents the remaining
length required to reach the end of the
shelter. Consult Spec Sheet and Side Profile
diagrams for part identification.
Assembly Procedure
Example of a "fan-folded" cover.
Frame Position
Secure this conduit
to the ratchets
during cover install.
Pull this
conduit
over frame.
Conduit
8