After splicing the cassettes, reinstall them into the
bulkhead.
Coil up the buffer tubes from each cassette into a
coil around 6-7" in diameter.
The coil can then be secured with the provided
velcro.
The buffer tubes can then
be inserted into the panel,
either above or below the
cassettes.
Reinstall the back panel,
pushing in the plungers to
secure it in place.
1RU Panels
Note: Panels shown in images may not match product received. Splicing in cassettes and buffer tube storage will
remain functionally the same.
When using the 1RU panel, use the following
steps to store the buffer tube slack in the panel
after splicing, as 1RU panels do not include a
slack basket due to buffer tube bend limitations.
Note:
If the buffer tube used in splicing a 2RU
panel is too stiff to coil in the slack basket, the
slack can be stored in the same fashion as the
1RU panel.
1.
2.
3.
4.
5.