25
FieldSmart
®
FxMP Panel & Standard Frame
__________________________________________________________
Installation Manual
Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • [email protected]
Manual 019807 REV A - June 2018
6.
Feed the remaining buffer tubes through the left side of the panel (looking from the rear of the panel), interweaving
the new buffer tubes with the existing ones on the right. Buffer tubes from the left and right sides should alternate as
shown.
After splicing, feed the buffer tubes back
through the bulkhead and install the cassettes
into the panel in the appropriate locations.
5.
7.
Proceed to splicing the buffer tubes into the
cassettes for the second half of the panel.
After splicing is complete, feed the buffer
tubes back through the panel and install the
cassettes into their corresponding slots.