1. Find and identify ideal mounting location for relay box on rooftop rack mounting. 
2. Identify up to 3 optimal panels to use for wiring into the ​

ClearPOWER​

 Docking Station to charge 

ClearPOWER​

 ClearPOWER P2. 

3. Using MC4 connectors and Y Branch connector to split the + and – leads from each solar panel before the 

micro-inverter and/or optimizer. 

4. Attach the + and – leads to the relay box. 
5. Using approved methods bring #10 AWG wire from the ​

ClearPOWER​

 RelayBox to the installed 4 Square 

Box dedicated to the ​

ClearPOWER​

 DockingStation. 

6. Run outside rated #18 AWG (signal wires) from the ​

ClearPOWER​

 RelayBox to the 4 Square box dedicated 

to the ​

ClearPOWER​

 DockingStation. 

7. Connect solar wires in the RelayBox and junction box. 
8. Connect the signal wires in the RelayBox and in the Junction Box. 
9. Re-install plates and re-mount solar panels  
10. Test 
 

 

 
 

Tool 

Appearance 

Description 

Multimeter 

 

Used to check cabinet insulation 
and cable connection, and 
measure electronic performance 
specifications of a device, such as 
voltage, current, and resistance. 

Label paper 

 

Used to prepare labels. 

Insulated phillips screwdriver (2 
mm x 150 mm and 3 mm x 250 
mm) 

 

Used to tighten screws and bolts. 

Summary of Contents for ClearPOWER P2

Page 1: ......

Page 2: ...ClearPOWER P2 is an all in one plug n play energy charging storage and powering solution It can power refrigerators lights TV s internet modems microwaves fans and more if your home loses power from...

Page 3: ...circuit breaker in the load center before starting installation 1 Identify installation location of the Docking Station Most installations are done in utility rooms in proximity to the home s breaker...

Page 4: ...he 4 Square Box 4 Label and Mark wires according to the provided wiring diagram in order to easily match with the labeled wires on the ClearPOWER installation cable 5 Connect to corresponding wires on...

Page 5: ...ox dedicated to the ClearPOWER DockingStation 6 Run outside rated 18 AWG signal wires from the ClearPOWER RelayBox to the 4 Square box dedicated to the ClearPOWER DockingStation 7 Connect solar wires...

Page 6: ...d to cut insulation cables and cable ties Wire stripper Used to remove the insulation layer and jacket from a communication cable with a small cross sectional area PVC insulation tape Used to insulate...

Page 7: ...Used to prevent the electrostatic discharge ESD from damaging a board or other electrostatic sensitive devices ESSDs when you insert or remove a board or hold an ESSD Insulated gloves Used to insulat...

Page 8: ...o Docking Station White 14 AWG 3 Circuit 1 From Breaker Red 12 AWG 4 Circuit 2 From Breaker Red 12 AWG 5 Circuit 3 From Breaker Red 12 AWG 6 Appliance Circuit 3 Black 12 AWG 7 Neutral 1 to Neutral Bar...

Reviews: