background image

 

 
 

 
 

1. PV Wire + (Red) #10 AWG 
2. PV Wire – (Black) #10 AWG 
3. Control Wire (Purple) #18 AWG 
4. Control Wire (Orange) #18 AWG 
5. Ground (Green) # 6 AWG 

 
 

 
 
 

 

1. Power to Docking Station (Black) #14 AWG 
2. Neutral to Docking Station (White) #14 AWG 
3. Circuit #1 From Breaker (Red) #12 AWG 
4. Circuit #2 From Breaker (Red) #12 AWG 
5. Circuit #3 From Breaker (Red) #12 AWG 
6. Appliance/Circuit #3 (Black) # 12 AWG 
7. Neutral #1 to Neutral Bar (White) #14 AWG 
8. Appliance/Circuit #2 (Black) #12 AWG 
9. Neutral #2 to Neutral Bar (White) #14 AWG 
10. Appliance/Circuit #1 (Black) # 12 AWG 
11. Neutral #3 to Neutral Bar (White) #14 AWG 
12. Empty 
 

 
 
 

 

 
 
 

Summary of Contents for ClearPOWER P2

Page 1: ......

Page 2: ...ClearPOWER P2 is an all in one plug n play energy charging storage and powering solution It can power refrigerators lights TV s internet modems microwaves fans and more if your home loses power from...

Page 3: ...circuit breaker in the load center before starting installation 1 Identify installation location of the Docking Station Most installations are done in utility rooms in proximity to the home s breaker...

Page 4: ...he 4 Square Box 4 Label and Mark wires according to the provided wiring diagram in order to easily match with the labeled wires on the ClearPOWER installation cable 5 Connect to corresponding wires on...

Page 5: ...ox dedicated to the ClearPOWER DockingStation 6 Run outside rated 18 AWG signal wires from the ClearPOWER RelayBox to the 4 Square box dedicated to the ClearPOWER DockingStation 7 Connect solar wires...

Page 6: ...d to cut insulation cables and cable ties Wire stripper Used to remove the insulation layer and jacket from a communication cable with a small cross sectional area PVC insulation tape Used to insulate...

Page 7: ...Used to prevent the electrostatic discharge ESD from damaging a board or other electrostatic sensitive devices ESSDs when you insert or remove a board or hold an ESSD Insulated gloves Used to insulat...

Page 8: ...o Docking Station White 14 AWG 3 Circuit 1 From Breaker Red 12 AWG 4 Circuit 2 From Breaker Red 12 AWG 5 Circuit 3 From Breaker Red 12 AWG 6 Appliance Circuit 3 Black 12 AWG 7 Neutral 1 to Neutral Bar...

Reviews: