70
www.clearcom.com
BeltStation
BeltStation will not power up
•
Confirm that battery(ies) is (are) installed correctly.
•
When using a Lithium-Polymer rechargeable battery, ensure that the battery is fully charged.
•
When using alkaline AA batteries ensure that batteries are fresh and are all facing the same way. Note the illustration
in the battery compartment section.
•
Press and hold the Power button on the back of the BeltStation for two seconds to power on.
BeltStation will not pair with BaseStation
•
Confirm that the BaseStation you are pairing with is powered on and in Operational Mode and the BeltStation is
powered OFF. Connect the pairing cable from the BaseStation to the BeltStation. Turn the BeltStation power ON.
The pairing process takes approximately four seconds.
•
If pairing is successful the message “Pairing Complete” will appear on the BeltStation LCD for approximately five
seconds and the BeltStation name will appear in the first available slot on the BaseStation LCD. The BaseStation
name will appear on the BeltStation LCD. If pairing is not successful no message will appear.
•
If pairing is not successful try to pair a different BeltStation with the BaseStation. If neither of the BeltStations
will pair, substitute a new Pairing cable.
•
If successful pairing any BeltStation with the BaseStation, try the following procedure on the BeltStation that will
not pair:
»
Restore memory settings to Factory Defaults by pressing MENU
»
Select “Belt Settings,” select “Tech Menu,” press ENTER to proceed
»
Select “Set Defaults,” select
Restore Factory Defaults
, press ENTER to confirm and press MENU to exit
•
If still not successful, repeat the above procedure but select
Clear Memory
to delete all memory settings, pairings,
and user settings.
See “Factory Defaults” section for more detail.
•
If no BeltStation will pair with the BaseStation, reset the BaseStation memory to “Factory Defaults”.
•
The final option is to select “Clear Memory” to fully reset the BaseStation. All BeltStation pairings will be lost with the
“Clear Memory” option.
See “Factory Defaults” section for more detail.
BeltStation will not log into BaseStation
•
Confirm that the BeltStation is powered ON and has a battery with ample charge.
•
Confirm that the proper BaseStation is selected on the BeltStation’s “Select Base” menu.
•
Confirm that there is an available slot on the BaseStation.
•
Check
Static
and
Dynamic
slot display settings on the BaseStation. If
Static
is selected check the BeltStation slot
assignment.
•
Determine if any BeltStation is logged onto the BaseStation.
•
Re-pair the BeltStation to the BaseStation.
•
Attempt to log into another BaseStation, if available.
•
Follow the memory reset procedure under “Factory Defaults.”
Summary of Contents for Tempest2400
Page 1: ...2 Channel Wireless Intercom Reference Manual Tempest 2400...
Page 2: ......
Page 8: ...iv www clearcom com This page intentionally left blank...
Page 13: ...Clear Com Tempest 2400 2 Channel Wireless Intercom System 5 This page intentionally left blank...
Page 59: ...Clear Com Tempest 2400 2 Channel Wireless Intercom System 51 BaseStation Menu...
Page 71: ...Clear Com Tempest 2400 2 Channel Wireless Intercom System 63 BeltStation Menu...
Page 80: ...72 www clearcom com This page intentionally left blank...
Page 86: ...78 www clearcom com This page intentionally left blank...
Page 96: ...88 www clearcom com Tempest Block Diagram...
Page 97: ...Clear Com Tempest 2400 2 Channel Wireless Intercom System 89 Tempest Block Diagram continued...
Page 100: ...92 www clearcom com This page intentionally left blank...
Page 102: ...www clearcom com...