6.4.3 Connecting E-MADI64 Audio (using Coaxial or Fiber cable)
When you connect the external E-MADI64 Audio (using Coaxial or Fiber cable) to the rear of the
E-MADI64 card:
1. The sample rate and the number of configured ports is indicated by a
solid green
LED on the
front of the E-MADI64 card.
2. The
red
Error
LED on the E-MADI64 card is
turned off
.
3. When the number of received channels differs from the number of channels configured in
EHX, the
Channel
LEDs on the front of the E-MADI64 card
flash green
, oscillating between
2 types of port numbers.
4. When the received sample rate differs from the configured sample rate, the Sample rate
LEDs on the front of the E-MADI64 card
flash green
, oscillating between 2 types of sample
rates.
5. Audio passes into and out of the E-MADI64 card to the HX-Median backplane.
6.5 Upgrading the E-MADI64 card
The E-MADI64 card is both
centrally
upgradable (you can upgrade the E-MADI64 thru the matrix
frame, using EHX) and locally upgradeable, using Xilinx software, a PC and a Xilinx download cable.
For more information, see the
Eclipse HX Upgrade Guide
.
81
Eclipse HX-Median User Guide