CleanSpace Respirators USER INSTRUCTIONS
20
English
English
CHECK THAT THE MASK SEAL DOES NOT CROSS YOUR HAIRLINE
Check all the way around the mask seal, paying particular attention to your forehead and temples.
The seal must not cross
your hairline
.
IF YOU CANNOT ADJUST THE MASK TO AVOID YOUR HAIRLINE, THE MASK IS NOT SUITABLE FOR YOU AND MUST NOT BE
WORN
Check that there is no loose hair between the silicone mask
seal and your face
You will not be able to achieve a good fit if there are any
strands of hair between the mask and your face.
Carry out a negative pressure seal check
Using your finger or thumb, cover the air inlet (on the left hand
mask air clip).
Breathe in sharply. You should not be able to draw any air into
the mask. The mask should be sucked in towards your face as
you inhale. Listen for squeaking or whistling noises which
indicate air is leaking past the seal.
Hold your breath for 10 seconds. The mask should stay
collapsed against your face. If the mask seal slowly recovers
(mask moves away from your face) there is a leak. Readjust the
mask fit and repeat the negative pressure seal check.
IF A SATISFACTORY FIT CANNOT BE ACHIEVED, DO NOT ENTER THE CONTAMINATED ZONE
Place the machine in Standby Mode
Press the Power button
once
Don the respirator and start to breathe.
Place the respirator behind your head,
resting on your shoulders.
Note that the
hoop on the filter cover must be facing
upwards.
Grasp the left-hand mask AirClip in one
hand and the left-hand respirator AirClip
in the other. Join them. Pulling down on
the mask AirClip to move it away from
the harness makes this process easier.
Breathe normally. CleanSpace Respirator
should start.
If the motor does not start, it was not in
Standby Mode. Take the respirator off,
press the Power button to activate
Standby Mode and don it again as
described above.
Join the AirClips on the right hand side
NOTE! If you cannot connect the air clips on both sides because the respirator pulls up tight against the back of your neck,