Terminator Iron Filter Installation & Startup Guide
Page 8
www.cleanwaterstore.com
Rev 042414
Assembly and Installation Instructions
1.
Unscrew by hand the entire Fleck 2510 control valve from top of tank if it was shipped attached to
the tank. Place distributor tube in tank, if not already inside tank. If not already done, make sure
blue cap is on top of distributor tube, or wrap the top of distributor tube with electrical or duct tape.
You do not want gravel or filter media to go down the distributor tube.
2.
Add filter gravel supplied first, using the funnel sent with the Terminator iron filter.
Do not allow any parts of the media bag or other
foreign material to enter tank when adding media.
3.
Next mix all the Terminator media you received
together in a bucket. Add the media to the tank using
the funnel provided. Tank will be approximately 60%
full.
4.
Remove cap or tape from top of distributor tube.
5.
If possible at this point, fill tank to top with water.
6.
Attach optional plastic top screen to the under-side of
the Fleck 2510 control valve. It is a funnel-shaped
plastic screen that snaps on to the control valve and
prevents media from being backwashed out to drain during the regeneration cycles.
7.
Add a small amount of silicone grease or vegetable cooking oil to the Fleck 2510 control valve threads
and screw control valve carefully onto the softener tank, making sure not to cross-thread. Do not use