background image

7500

 

Pro

Ox

 

Filter

 

Installation

 

&

 

Startup

 

Guide

 

Page

 

5

 

www.cleanwaterstore.com

 

Rev

 

060116

 

Drain

 

Port.

  

From

 

the

 

male

 

pipe

 

thread

 

on

 

the

 

External

 

Flow

 

fitting,

 

you

 

can

 

transition

 

to

 

a

 

barb

 

fitting

 

and

 

run

 

tubing

 

to

 

where

 

you

 

need

 

to.

 

3.

 

Make

 

sure

 

there

 

is

 

a

 

working

 

gate

 

or

 

ball

 

valve

 

before

 

the

 

7500

 

Greensand

 

Filter

 

and

 

also

 

one

 

after

 

as

 

shown

 

in

 

Fig

 

2.

  

The

 

pressure

 

gauges

 

are

 

optional,

 

but

 

they

 

are

 

a

 

great

 

way

 

to

 

tell

 

at

 

a

 

glance

 

if

 

your

 

filter

 

needs

 

to

 

be

 

backwashed.

  

A

 

hose

 

bib

 

(which

 

is

 

a

 

faucet

 

to

 

which

 

you

 

can

 

attach

 

a

 

garden

 

hose)

 

is

 

strongly

 

recommended

 

after

 

the

 

Greensand

 

Filter

 

and

 

before

 

the

 

second

 

ball

 

valve.

  

This

 

makes

 

it

 

easy

 

to

 

rinse

 

your

 

new

 

Greensand

 

Filter

 

on

 

start

up

 

and

 

gives

 

you

 

a

 

place

 

to

 

test

 

the

 

water

 

before

 

it

 

enters

 

your

 

household

 

plumbing.

  

4.

 

If

 

you

 

will

 

be

 

using

 

copper

 

piping,

 

do

 

not

 

sweat

 

the

 

copper

 

pipe

 

directly

 

on

 

to

 

the

 

7500

 

control

 

valve.

  

Avoid

 

heating

 

up

 

the

 

7500

 

control

 

valve

 

plastic

 

with

 

the

 

torch.

 

5.

 

You

 

should

 

install

 

unions

 

and

 

a

 

bypass

 

around

 

the

 

valve,

 

so

 

that

 

you

 

can

 

remove

 

it

 

and

 

still

 

have

 

water.

 

6.

 

The

 

drain

 

line

 

tubing

 

(not

 

supplied)

 

is

 

connected

 

to

 

a

 

drain

 

from

 

the

 

External

 

Flow

 

Control

 

fitting

 

using

 

a

 

Female

 

X

 

Barbed

 

fitting

 

and

 

flexible

 

tubing.

   

Note

 

that

 

the

 

drain

 

can

 

run

 

up

 

above

 

the

 

7500

 

control

 

head

 

and

 

into

 

a

 

drain,

 

it

 

does

 

not

 

have

 

to

 

drain

 

down,

 

as

 

the

 

filter

 

backwashes

 

under

 

line

 

pressure

 

from

 

your

 

well

 

pump.

 

Most

 

plumbing

 

codes

 

require

 

an

 

air

gap

 

connection,

 

so

 

that

 

if

 

your

 

sewer

 

or

 

septic

 

tank

 

backs

 

up,

 

it

 

cannot

 

cross

 

connect

 

with

 

the

 

drain

 

tubing.

 

 

  

  

How

 

Your

 

Greensand

 

Filter

 

Works

 

See

 

Fig

 

1

 

on

 

the

 

right.

 

In

 

your

 

Greensand

 

Filter

 

the

 

water

 

enters

 

the

 

top

 

of

 

the

 

tank

 

(red

 

arrows)

 

and

 

flows

 

down

 

through

 

the

 

media

 

and

 

up

 

the

 

distributor

 

tube

 

(blue

 

arrows).

    

The

 

downflow

 

type

 

Greensand

 

Filter

 

removes

 

iron

 

and

 

can

 

be

 

backwashed,

 

which

 

cleans

 

and

 

re

classifies

 

the

 

media,

 

preventing

 

channeling.

  

During

 

backwash

 

the

 

flow

 

of

 

water

 

is

 

reversed

 

and

 

water

 

flows

 

down

 

the

 

distributor

 

tube

 

and

 

up

 

through

 

the

 

media,

 

lifting

 

and

 

expanding

 

the

 

Greensand

 

media.

 

During

 

the

 

backwash

 

the

 

media

 

is

 

cleaned

 

by

 

the

 

action

 

of

 

the

 

water

 

flowing

 

through

 

it.

 

                                          
                                                                            

Greensand

 

Media

 

Summary of Contents for Greensand 7500

Page 1: ...providing iron free water for many years Please review this start up guide entirely before beginning to install your system and follow the steps outlined for best results GREENSAND MEDIA CONTAINS DUST USE PAPER MASK AND VENTILATE TO AVOID BREATHING DUST Questions Call us toll free 1 888 600 5426 or 1 831 462 8500 Email us support cleanwaterstore com See more information on our website www cleanwat...

Page 2: ... 3 Greensand Filter 2 0 cubic foot size 3 Greensand Filter 2 5 cubic foot size 4 Pre Installation 4 Best Practices for Piping Drain Installation 4 Installation of Your System Into Copper or Metal Piping Systems 5 How Your Greensand Filter Works 5 Assembly and Installation Instructions 6 2 Basic Setting Usage 7 Programming the 7500 Valve 9 Typical Bypass assembly 11 Initial Backwash 12 How To Remov...

Page 3: ... Fitting 9 x 48 filter tank with distributor tube Blue media funnel for adding the Greensand media 12 lbs Filter gravel 1 cubic foot of Carbon media Greensand Filter 1 5 cubic foot size 7500 Backwash Control Valve 10 GPM External Drain line Flow Control Fitting 10 x 54 filter tank with distributor tube Blue media funnel for adding the Greensand media 16 lbs Filter gravel 1 5 cubic foot of Greensan...

Page 4: ...tion in case water heater is accidentally drained 3 Pick a suitable location for your filter system on a dry level spot where it won t be exposed to freezing temperatures A minimum of 20 PSI is required Maximum pressure is 90 PSI 4 Get all of your plumbing parts together before beginning installation and make sure you have received all of your packages before beginning or scheduling an installatio...

Page 5: ...tall unions and a bypass around the valve so that you can remove it and still have water 6 The drain line tubing not supplied is connected to a drain from the External Flow Control fitting using a Female X Barbed fitting and flexible tubing Note that the drain can run up above the 7500 control head and into a drain it does not have to drain down as the filter backwashes under line pressure from yo...

Page 6: ...Greensand media The tank should be about 2 3rds full of media do not fill more than 2 3rds even if there is some media left over 4 Remove tape from top of distributor tube Be careful not to pull up distributor tube when removing tape 5 Add 1 cup household bleach to inside distributor tube and fill Greensand Filter with water This will allow the Greensand Filter media to settle and eliminate the ne...

Page 7: ... Green Wrench Icon This indicates that you are in the programming menu and can change the values Red Backwash Icon three arrows pointing up underneath a rectangle with dots This indicates that you are programming the Backwash step or that the filter is in backwash Red Rapid Rinse Icon three arrows pointing down on top of a rectangle with dots This indicates that you are programming the Rapid Rinse...

Page 8: ...s explained later Menu Confirm Button the button on the far left an empty square with an arrow pointing left This is the button you press after you have unlocked the screen that puts you in the Service Menu so you can program the valve The first time you press it the Dynamic Display Stripe goes away and the Green Wrench icon appears Whichever of the Icons is lit at this time pressing the Menu Conf...

Page 9: ...Cycle Set the number of minutes for the Rapid Rinse Cycle When the green Wrench Icon is flashing whatever parameter that is selected set clock time set cycle step etc can now be adjusted by using the Scroll buttons For example When you press it the first time the Dynamic service Stripe goes away the Green Wrench Icon is lit and the other icon that is lit is the Blue Clock Icon that means that what...

Page 10: ...e time you set will now be displayed and not flashing Press the Scroll Down button to continue 3 This is the screen where you set what time of day the backwash will start 02 00 2 am is the default time The backwash cycle should be started while no one is using water and while no other filters you may also have are backwashing You will adjust the clock time for this as you did for the Current time ...

Page 11: ... item b 01 Press the Menu Confirm button and the Green Wrench Icon goes away the Dynamic Display Stripe returns and you are done programming your valve When the motor is turning 00 is displayed This valve can be used with Chemsorb sediment media Calcite Acid Neutralizer media Carbon Carbon media and different types of Iron Removal media Greensand Mang Ox Katalox lite and Greensand Typical Bypass a...

Page 12: ... Remove Media From Control Head Sometimes when doing the Initial Backwash the media gets lifted up into the control head You can tell this happened because you will have little or no flow either going out to drain while in the backwash positon or when in the service positon To remove media from a control head do the following 1 Put the Inlet Bypass in the Closed position 2 From the Service Mode in...

Page 13: ...you plug the valve back in after a minute it will return to where it was when you unplugged it i e 2 32 remaining in BW Understand it is not possible to jam media into the head while in Rapid Rinse or Service just in the Backwash when the flow direction is reversed What you are trying to accomplish after you have pushed the media back in to the tank in the Rapid Rinse position is to get the Inlet ...

Reviews: