background image

7500

 

Pro

Ox

 

Filter

 

Installation

 

&

 

Startup

 

Guide

 

Page

 

4

 

www.cleanwaterstore.com

 

Rev

 

060116

 

Greensand

 

Filter

 

2.5

 

cubic

 

foot

 

size

  

7500

 

Backwash

 

Control

  

15

 

GPM

 

External

 

Drain

 

line

 

Flow

 

Control

 

Fitting

 

12”

 

x

 

52”

 

filter

 

tank

 

with

 

distributor

 

tube

 

Blue

 

media

 

funnel

 

for

 

adding

 

the

 

Greensand

 

media

 

20

 

lbs.

 

Filter

 

gravel

 

and

 

2.0

 

cubic

 

foot

 

of

 

Greensand

 

media

 

 

Greensand

 

Filter

 

3.0

 

cubic

 

foot

 

size

  

7500

 

Backwash

 

Control

  

20

 

GPM

 

External

 

Drain

 

line

 

Flow

 

Control

 

Fitting

 

12”

 

x

 

52”

 

filter

 

tank

 

with

 

distributor

 

tube

 

Blue

 

media

 

funnel

 

for

 

adding

 

the

 

Greensand

 

media

 

20

 

lbs.

 

Filter

 

gravel

 

and

 

2.0

 

cubic

 

foot

 

of

 

Greensand

 

media

 

 

Pre

Installation

 

1.

 

Review

 

your

 

packing

 

list

 

and

 

make

 

sure

 

you

 

have

 

received

 

all

 

the

 

parts

 

before

 

beginning

 

installation.

 

2.

 

If

 

you

 

are

 

going

 

to

 

be

 

turning

 

off

 

the

 

water

 

to

 

the

 

house

 

and

 

you

 

have

 

an

 

electric

 

water

 

heater,

 

shut

 

off

 

the

 

power

 

to

 

the

 

water

 

heater

 

before

 

beginning

 

installation

 

in

 

case

 

water

 

heater

 

is

 

accidentally

 

drained.

 

3.

 

Pick

 

a

 

suitable

 

location

 

for

 

your

 

filter

 

system

 

on

 

a

 

dry

 

level

 

spot

 

where

 

it

 

won’t

 

be

 

exposed

 

to

 

freezing

 

temperatures.

 

A

 

minimum

 

of

 

20

 

PSI

 

is

 

required.

  

Maximum

 

pressure

 

is

 

90

 

PSI.

 

4.

 

Get

 

all

 

of

 

your

 

plumbing

 

parts

 

together

 

before

 

beginning

 

installation,

 

and

 

make

 

sure

 

you

 

have

 

received

 

all

 

of

 

your

 

packages

 

before

 

beginning

 

or

 

scheduling

 

an

 

installation.

 

Installation

 

typically

 

takes

 

3

 

to

 

5

 

hours.

 

However,

 

after

 

installation

 

the

 

Greensand

 

Filter

 

must

 

be

 

allowed

 

to

 

run

 

through

 

a

 

complete

 

backwash

 

and

 

rinse

 

cycle.

   

5.

 

After

 

the

 

system

 

is

 

installed

 

and

 

running,

 

your

 

water

 

may

 

be

 

discolored,

 

or

 

full

 

of

 

sediment

 

or

 

rust,

 

particularly

 

if

 

this

 

is

 

older

 

or

 

corroded

 

piping.

 

This

 

typically

 

clears

 

up

 

over

 

a

 

day

 

or

 

two.

 

Best

 

Practices

 

for

 

Piping

 

&

 

Drain

 

Installation

 

1.

 

See

 

typical

 

installation

 

on

 

page

 

7

 

(Fig

 

2).

   

The

 

Greensand

 

filter

 

is

 

installed

 

after

 

the

 

pressure

 

tank.

 

2.

 

Make

 

sure

 

to

 

connect

 

the

 

Inlet

 

from

 

your

 

water

 

source.

  

Make

 

sure

 

to

 

connect

 

the

 

Outlet

 

to

 

where

 

the

 

water

 

is

 

being

 

used

 

and

 

be

 

sure

 

and

 

install

 

the

 

External

 

Flow

 

Control

 

fitting

 

onto

 

the

 

Summary of Contents for Greensand 7500

Page 1: ...providing iron free water for many years Please review this start up guide entirely before beginning to install your system and follow the steps outlined for best results GREENSAND MEDIA CONTAINS DUST USE PAPER MASK AND VENTILATE TO AVOID BREATHING DUST Questions Call us toll free 1 888 600 5426 or 1 831 462 8500 Email us support cleanwaterstore com See more information on our website www cleanwat...

Page 2: ... 3 Greensand Filter 2 0 cubic foot size 3 Greensand Filter 2 5 cubic foot size 4 Pre Installation 4 Best Practices for Piping Drain Installation 4 Installation of Your System Into Copper or Metal Piping Systems 5 How Your Greensand Filter Works 5 Assembly and Installation Instructions 6 2 Basic Setting Usage 7 Programming the 7500 Valve 9 Typical Bypass assembly 11 Initial Backwash 12 How To Remov...

Page 3: ... Fitting 9 x 48 filter tank with distributor tube Blue media funnel for adding the Greensand media 12 lbs Filter gravel 1 cubic foot of Carbon media Greensand Filter 1 5 cubic foot size 7500 Backwash Control Valve 10 GPM External Drain line Flow Control Fitting 10 x 54 filter tank with distributor tube Blue media funnel for adding the Greensand media 16 lbs Filter gravel 1 5 cubic foot of Greensan...

Page 4: ...tion in case water heater is accidentally drained 3 Pick a suitable location for your filter system on a dry level spot where it won t be exposed to freezing temperatures A minimum of 20 PSI is required Maximum pressure is 90 PSI 4 Get all of your plumbing parts together before beginning installation and make sure you have received all of your packages before beginning or scheduling an installatio...

Page 5: ...tall unions and a bypass around the valve so that you can remove it and still have water 6 The drain line tubing not supplied is connected to a drain from the External Flow Control fitting using a Female X Barbed fitting and flexible tubing Note that the drain can run up above the 7500 control head and into a drain it does not have to drain down as the filter backwashes under line pressure from yo...

Page 6: ...Greensand media The tank should be about 2 3rds full of media do not fill more than 2 3rds even if there is some media left over 4 Remove tape from top of distributor tube Be careful not to pull up distributor tube when removing tape 5 Add 1 cup household bleach to inside distributor tube and fill Greensand Filter with water This will allow the Greensand Filter media to settle and eliminate the ne...

Page 7: ... Green Wrench Icon This indicates that you are in the programming menu and can change the values Red Backwash Icon three arrows pointing up underneath a rectangle with dots This indicates that you are programming the Backwash step or that the filter is in backwash Red Rapid Rinse Icon three arrows pointing down on top of a rectangle with dots This indicates that you are programming the Rapid Rinse...

Page 8: ...s explained later Menu Confirm Button the button on the far left an empty square with an arrow pointing left This is the button you press after you have unlocked the screen that puts you in the Service Menu so you can program the valve The first time you press it the Dynamic Display Stripe goes away and the Green Wrench icon appears Whichever of the Icons is lit at this time pressing the Menu Conf...

Page 9: ...Cycle Set the number of minutes for the Rapid Rinse Cycle When the green Wrench Icon is flashing whatever parameter that is selected set clock time set cycle step etc can now be adjusted by using the Scroll buttons For example When you press it the first time the Dynamic service Stripe goes away the Green Wrench Icon is lit and the other icon that is lit is the Blue Clock Icon that means that what...

Page 10: ...e time you set will now be displayed and not flashing Press the Scroll Down button to continue 3 This is the screen where you set what time of day the backwash will start 02 00 2 am is the default time The backwash cycle should be started while no one is using water and while no other filters you may also have are backwashing You will adjust the clock time for this as you did for the Current time ...

Page 11: ... item b 01 Press the Menu Confirm button and the Green Wrench Icon goes away the Dynamic Display Stripe returns and you are done programming your valve When the motor is turning 00 is displayed This valve can be used with Chemsorb sediment media Calcite Acid Neutralizer media Carbon Carbon media and different types of Iron Removal media Greensand Mang Ox Katalox lite and Greensand Typical Bypass a...

Page 12: ... Remove Media From Control Head Sometimes when doing the Initial Backwash the media gets lifted up into the control head You can tell this happened because you will have little or no flow either going out to drain while in the backwash positon or when in the service positon To remove media from a control head do the following 1 Put the Inlet Bypass in the Closed position 2 From the Service Mode in...

Page 13: ...you plug the valve back in after a minute it will return to where it was when you unplugged it i e 2 32 remaining in BW Understand it is not possible to jam media into the head while in Rapid Rinse or Service just in the Backwash when the flow direction is reversed What you are trying to accomplish after you have pushed the media back in to the tank in the Rapid Rinse position is to get the Inlet ...

Reviews: