6
Figure 3: Mounting the Pump Assembly
(1) Refer to Figure 3.
(2) Use four large self-drilling screws
to secure the pump mounting plate
to the 2” X 2” vertical posts. It is
recommended to place the pump
directly above the drain pan. This
becomes helpful when the filter is
being cleaned.
(3) Use four serrated flange cap
screws and nuts to secure the
pump to the mounting plate.
(4) Refer to the furnace Owner’s
Manual for instructions on
connecting the oil lines and wiring
the metering pump to the furnace.
Mounting the Pump Assembly:
Mounting the Drain Pan:
(1) Refer to Figure 2
(2) Assemble the drain pan, ball valve,
and pipe
(3) Install the 2” tank bushing in the
open port directly below the location
of the drain pan (on the left side
when facing the tank)
(4) Slide the pipe through the 2”
bushing and use two of the provided
large self-drilling screws to mount
the drain pan to the vertical
2” X 2” posts
HEATING CENTER ASSEMBLY
Figure 2: Mounting the Drain Pan
2" TANK
BUSHING
1/2" PIPE
BALL
VALVE
LARGE SELF
DRILLING
SCREWS
4" EMERGENCY
VENT
2" DUPLEX
FITTING
CE70070
CE70071
SERRATED
FLANGE CAP
SCREWS (X4)
LARGE SELF
DRILLING
SCREWS (X4)