FILTRATION
FILTRATION
WWW.CLEANCOMFORT.COM
10
MAINTENANCE
IO-AE14-5
Reinstalling the Cells and Prefilters
1. Once dry, inspect the cells for broken ionizer wires
and bent collector plates. Repair as necessary or
contact an authorized Clean Comfort service
technician to repair.
2. Re-insert the prefilters into the upstream
prefilter guides.
3. Re-insert the collector cells into the guides in the
bottom center of the air cleaner cabinet; the airflow
arrow points downstream (towards the furnace or
air handler) and the handle faces outward.
4. Firmly close the access door and turn power switch
ON
. If the performance light does not come on or
arcing occurs, turn air cleaner
OFF
and allow air from
system fan to dry cells completely.
Replacing the Carbon VOC Filters
1. The activated carbon VOC filters help remove odors
and light gases from the air exiting the air cleaner.
They should be replaced every six months, or more
frequently with heavy use and should be done as part
of the scheduled cleaning when the cells and prefilters
are cleaned. Carbon VOC Filters are NOT washable.
2. Replacement carbon VOC filters are available in the
same size and configuration as the original unit. They
can be purchased from your Clean Comfort authorized
service technician.
1. Turn air cleaner power switch
OFF
2. Turn
OFF
system fan
3. Open access door
4. Remove collecting cells from air cleaner
5. Remove the used carbon VOC filters from air cleaner
6. Put new carbon VOC filters into air cleaner. Space filters
evenly across the discharge opening of air cleaner.
Never put more than 3 carbon VOC filters in the air
cleaner, as this may cause a problem with airflow.
Figure 7:
DAX Detergent and Carbon VOC Filters are available
from your installer or dealer.
Maintenance Parts
Item
Part #
DAX 32 oz Spray Bottle
AEP-FS9900
Replacement Carbon VOC Filters:
AE14-1620-51,-52 (Set of 3)
AEP-1156-3
AE14-1625-51,-52 (Set of 3)
AEP-1156-3
AE14-2020-51,-52 (Set of 3)
AEP-1856-3
AE14-2025-51,-52 (Set of 3)
AEP-1856-3
Cleaning Record
The collecting cells and prefilters must be cleaned on a
regular basis for the air cleaner to function at its peak
efficiency. The frequency of cleaning will vary from
one house to another. On average, the cells should be
cleaned every 3 months. Use the chart below to keep
track of your cleaning schedule.
Cleaning Record
Date Cleaned
Performed by