4
or a safety helmet, is not recommended for users
with beard or long hair extending to the respiratory
zone.
• Beware of a higher CO
2
concentration in the air-
supply, which may occur if the compressor does
not work properly, when the lubricating oil someti-
mes burns due to high temperatures.
• The supply air pressure must be within the range
between 400 - 1000 kPa.
• The supply pressure hoses may only be located in
such places of the workplace where they cannot
be damaged.
• Pressure hoses for CA Pressure (Flow Master) and
CAP Conditioner, order No. 61 00 30 and 61 00 46,
are not antistatic and the maximum temperature to
which they are resistant without damage is 70 °C.
• The maximum length of the hose from the
compressed air distribution or CAP Conditioner to
the unit must not exceed 10 m.
• The recommended temperature range of use is
10 - 40 °C; at lower temperatures, the use of the
protective hood or mask with air supply may be
unpleasant.
• Before connecting the unit to the air distribution, it
is necessary to check what medium is in the line
and what is its quality.
• For the CA Pressure (Flow Master) it is necessary
to provide breathable air according to EN 12021.
• The CA Pressure units can be combined with the
types of head parts shown in the pictorial annex.
It shows also classes for the respective combina-
tions.
• Information on head parts are provided in the in-
structions for use of the CA head parts.
If any principles stated in this manual are breached,
the warranty becomes null and void!
3. Unpacking / Assembly /
Use and Functions
3.1.
Unpacking CA Pressure
Check that the delivery is complete and no damage
occurred during transport.
Content of the CA Pressure (63 00 00), CA Pressu-
re Flow Master (67 00 00) contain:
CleanAIR® Pressure (Flow Master) unit
1 pc
Belt for the unit
1 pc
Air flow indicator
1 pc
User manual
1 pc
Content of the CA Pressure Conditioner (61 00 50):
CA Pressure Conditioner unit
1 pc
Unit stand
1 pc
Screws for connecting the unit to the stand 2 pcs
Gasket
4 pcs
Instruction for Use
1 pc
3.2. Assembly
CA Pressure (Flow Master) + CAP Conditioner
• Check that all components are in good condition,
i.e. without apparent damage.
• Connect CAP Conditioner to the compressed air
distribution system or straight to a compressor.
The air source must be equipped with a safety
valve (if CA Pressure Conditioner is not used, the
compressed air supply is connected straight to CA
Pressure (Flow Master).
• It is recommended using only original hoses supp-
lied by the manufacturer certified according to the
applicable standard.
• Check that the air pressure in the distribution sys-
tem corresponds to the range 300 to 1000 kPa.
• Attach the unit onto your belt and fit the connecti-
ng hose to it.
• Using the quick coupling, connect the pressure
hose from the compressed air source to the CA
Pressure unit. The hose from CAP Conditioner to
CA Pressure must not be longer than 10 metres.
• Check the air flow according to Chapter 4.2. The
lowest allowable flow rate is 170 l/min.
3.3. Assembling CAP Conditioner (61 00 50)
Screw the pressure vessel body onto the stand; for
the procedure see pictorial annex 1A.
Summary of Contents for Pressure
Page 2: ......
Page 13: ...13 CA Pressure conditioner assembly 1A Airflow adjustment CA Pressure CA FM 2A 2B 2C ...
Page 15: ...15 ...
Page 16: ...16 ...