9
Attach the four(4) spring handles to the Feed/Ash Doors, Baffl
e
Rod, and Shaker Rod by twisting the springs counter-clockwise
while applying pressure until you have screwed them approxi-
mately 3/4”-1” onto the rods.
(4) Spring Handles
Item
Description
Qty.
A
800 CFM Blower
(2)
B
Gasket, Blower
(2)
C
Tinnerman Clip, 1/4-20
(8)
D
1/4-20 x 3/4 Bolt
(8)
E
Conduit Assembly (5ft )
(2)
F
Honeywell Limit Control
(1)
G
Conduit Assembly (1ft )
(1)
H
Junction Box
(1)
1. Remove all contents and insure that all components are
present for assembly. See the part list below
2. Begin by attaching the blowers to the unit. Insert a clip into
each mounting hole in the furnace’s cabinet back. Be sure
to install the gasket between the blower and cabinet back.
Insert the eight bolts provided and tighten.
3. Mount the Honeywell limit control to the cabinet back.
Th
e conduit assembly should already be attached to the
limit control, otherwise, do so then make the correct wir-
ing connections to the limit control. See wiring diagram.
4. Next, mount the junction box and insulation using two of
the #10 x 1/2 screws provided. Make a small slice in the
5 x 5 insulation to allow the wires from the draft blower
to protrude, then Install it between the cabinet back and
junction box, with the foil side to the cabinet back. Attach
the conduit assembly from the limit control to the junction
box as shown.
5. If not already installed, snap the rocker switch into the top
of the junction box. Provide a 110 volt power supply and
connect to the junction box with the cable clamp to the
right side.
6. Attach the two longer conduit assemblies to the junction
box and to each blower.
7. Before mounting the Fan Center, make all the wire con-
nections per the wiring diagram, then attach the fan center
to the junction box.
All electrical connections should be done by a qualifi ed electri-
cian. NOTE: Th
e extra brown wire on the fan center has no
use. It should be capped off or removed.Th
e conduit may be cut
shorter to provide a cleaner installation.
A
B
C
E
H
G
K
D
J
I
F
SPRING HANDLES
WIRING DIAGRAM
DISTRIBUTION BLOWER & ACC.
I
Rocker Switch
(1)
J
Romex Cable Clamp
(1)
K
Fan Center Control
(1)
-
73B Wire Nut
(3)
-
74B Wire Nut
(1)
-
Female Term. (blue)
(1)
-
Female Term. (red)
(1)
-
#10 x 1/2 Screw
(8)